![Huawei Quidway S9300 Configuration Manual - Network Management Download Page 348](http://html.mh-extra.com/html/huawei/quidway-s9300/quidway-s9300_configuration-manual-network-management_169487348.webp)
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
nqa
test-instance
admin-name
test-name
An NQA test instance is created and the test instance view is displayed.
Step 3
Run:
send-trap
{
owd-ds
|
owd-sd
}*
Sending trap messages when the transmission delay exceeds the threshold is enabled.
By default, the trap function is disabled.
----End
6.33.6 Checking the Configuration
After the trap function is enabled in an NQA test instance, you can view trap messages in the
trap buffer.
Prerequisite
The configurations of the Trap function are complete.
Procedure
Step 1
Run the
display trapbuffer
[
size
value
] to view the trap messages sent in an NQA test.
----End
Example
Run the
display trapbuffer
[
size
value
] command. If information about the trap messages is
displayed, it means that the configuration succeeds.
For example:
<Quidway>
display trapbuffer size 2
Trapping Buffer Configuration and contents:enabled
allowed max buffer size : 1024
actual buffer size : 256
channel number : 3 , channel name : trapbuffer
dropped messages : 0
overwritten messages : 0
current messages : 11
#May 6 2009 12:54:17 CBB6-PE3 SINDEX/4/INDEXMAP:OID
1.3.6.1.4.1.2011.5.25.110.2.0.1 ShortIFIndexMapTable changed.
#May 6 2009 11:02:37 CBB6-PE3 SRM_BASE/4/ENTITYREGSUCCESS: OID
1.3.6.1.4.1.2011.5.25.129.2.1.18 Physical entity register succeeded.
(EntityPhysicalIndex=17367040, BaseTrapSeverity=2, BaseTrapProbableCause=70144,
BaseTrapEventType=5, EntPhysicalContainedIn=1677721
6, EntPhysicalName="SRU slot 9", RelativeResource="", ReasonDescription="MPU9")
6 NQA Configuration
Quidway S9300 Terabit Routing Switch
Configuration Guide - Network Management
6-128
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 03 (2010-09-20)