![Huawei Quidway S9300 Configuration Manual - Network Management Download Page 347](http://html.mh-extra.com/html/huawei/quidway-s9300/quidway-s9300_configuration-manual-network-management_169487347.webp)
The system view is displayed.
Step 2
Run:
nqa
test-instance
admin-name
test-name
An NQA test instance is created and the test instance view is displayed.
Step 3
Run:
send-trap
probefailure
Sending trap messages when probes fail is enabled.
By default, the trap function is disabled.
Step 4
Run:
probe-failtimes
times
The number probe failures that trigger sending a Trap message is configured.
By default, a trap message is sent for each probe failure.
----End
6.33.4 Sending Trap Messages When Probes Are Complete
A trap message is sent to the NMS when the NQA test is complete.
Context
Do as follows on the NQA client:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
nqa
test-instance
admin-name
test-name
An NQA test instance is created and the test instance view is displayed.
Step 3
Run:
send-trap
testcomplete
Sending trap messages when tests are completed is enabled.
By default, the trap function is disabled.
----End
6.33.5 Sending Trap Messages When the Transmission Delay
Exceeds Thresholds
A trap message is sent to the NMS when the test result exceeds the threshold.
Context
Do as follows on the NQA client:
Quidway S9300 Terabit Routing Switch
Configuration Guide - Network Management
6 NQA Configuration
Issue 03 (2010-09-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6-127