Command Manual – PoE
Quidway S8500 Series Routing Switches
Chapter 2 PoE PSU Supervision Commands
Huawei Technologies Proprietary
2-2
2.1.2 display poe-power alarm
Syntax
display poe-power alarm
View
Any view
Parameter
None
Description
Use the
display poe-power alarm
command to display detailed alarm information
about the PoE PSUs.
Example
# Display detailed alarm information about the PoE PSUs.
<Quidway> display poe-power alarm
PSU alarm detail, PSU number : 2
PSU 1 alarm : NORMAL
PSU 2 alarm : NOTLINK Controller/Rectifer communication Fail/Rectifier
not in present
Table 2-2
Description on the fields of the
display poe-power alarm
command
Field
Description
NORMAL Normal
NOTLINK
The PSU is disconnected. That is, the controller was able to
communicate with the PSU; but it cannot now. Power-cycling the
unit or re-inserting a new PSU can resolve this problem.
INERROR
The PSU input is in trouble. Restoring the AC input can resolve
this problem.
OUTERROR
The PSU output is in trouble, the PSU cannot output normal DC
voltage.
HIGHVOL
The PSU is over-voltage. The PSU is shut down because the
output voltage is too high.
HIGHTEP
It is overheated in the PSU.
FANERROR
The PSU fan is in trouble.
CLOSE
The PSU is shut down remotely.
CURLIMIT
The PSU is current limited.