Command Manual – PoE
Quidway S8500 Series Routing Switches
Chapter 2 PoE PSU Supervision Commands
Huawei Technologies Proprietary
2-1
command
Chapter 2 PoE PSU Supervision Commands
2.1 PoE PSU Supervision Display Commands
2.1.1 display poe-power ac-input state
Syntax
display poe-power ac-input state
View
Any view
Parameter
None
Description
Use the
display poe-power ac-input state
command to display the AC input state of
each power supply unit (PSU).
Example
# Display the AC input state of each PSU.
<Quidway> display poe-power ac-input state
PSU 1 AC Input State : Lack Phase
PSU 2 AC Input State : Normal
PSU 3 AC Input State : Lack Phase
Table 2-1
Description on the fields of the
display poe-power ac-input state
Field
Description
NORMAL
The AC input is normal.
Under Limit
The AC input is below the lower threshold.
Upper Limit
The AC input is above the upper threshold.
Lack Phase
The AC input is lack of phase.
Fuse Broken
The fuse is blown.
Switch Off
The switch is off.