![Huawei Quidway S5600 Operation Manual Download Page 779](http://html.mh-extra.com/html/huawei/quidway-s5600/quidway-s5600_operation-manual_169841779.webp)
Operation Manual – Cluster
Quidway S5600 Series Ethernet Switches-Release 1510
Chapter 1 Cluster
Huawei Technologies Proprietary
1-8
Operation
Command
Description
Ente
r
Ethe
rnet
port
view
interface
interface-type
interface-number
the
specified
Ethernet
ports
In
Ether
net
port
view
Ena
ble
NDP
on
the
port
ndp enable
By default, NDP is enabled
on the port
1.2.3 Configuring NDP-related Parameters
Table 1-4
Configure NDP-related parameters
Operation
Command
Description
Enter system view
system-view
—
Configure the
holdtime of NDP
information
ndp timer aging
aging-in-seconds
Optional
By default, the aging time of
NDP packets is 180 seconds
Configure the
interval to send
NDP packets
ndp timer hello seconds
Optional
By default, the interval of
sending NDP packets is 60
seconds
1.2.4 Enabling NTDP Globally and for Specific Ports
Table 1-5
Enable NTDP globally and for specific ports
Operation
Command
Description
Enter system view
system-view
—
Enable NTDP
globally
ntdp enable
Required
Enter Ethernet port
view
interface
interface-type
interface-number
—
Enable NTDP for
the Ethernet port
ntdp enable
Required