Parameter
Description
Running
Status
This parameter indicates the running status of the PEM. There are the
following options:
l
Normal
: indicates that the power supply is running normally.
l
Power off
: indicates that the power supply is not connected.
l
Fault
: indicates that the power supply is faulty and cannot supply power
normally.
l
Absent
: indicates that the power supply is absent.
l
Over Voltage
: indicates that the input voltage of the power supply exceeds
the rated voltage of devices.
l
Under Voltage
: indicates that the input voltage of the power supply is less
than the rated voltage of devices.
Temperature
Status
This parameter indicates the temperature status of the PEM. The status can
be
Normal
and
Over Temperature
.
NOTE
Over Temperature
indicates that the PEM detects an overhigh temperature.
Type
This parameter indicates the PEM type. There are two options:
ACM
and
DCNM
.
Power
Version
This parameter indicates the version of the PEM software.
Vendor
This parameter indicates the manufacturer of the PEM.
Production
Date
This parameter indicates the production date of the PEM.
----End
Exception Handling
l
If the running status of the PEM is
Fault
, see “
” in the
OceanStor S5000 Series Storage System Alarm Reference
.
l
If an alarm that is related to the PEM is displayed on the alarm interface, handle it by
referring to the suggestion in the alarm items.
If the fault persists, contact the technical support engineers.
5.5 Checking the Status of the D200 Disk Subrack
This section describes how to check the D200 disk subrack through the OSM.
Reference Standard
l
No new alarms related to the disk subrack are displayed on the alarm interface.
l
The running status of all expander modules on the the disk subrack is
Normal
.
5 Routine Maintenance Guide of the OSM
OceanStor S5000 Series Storage System
Routine Maintenance
5-8
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 01 (2010-04-20)