Command Manual – 802.1x
Quidway S3900 Series Ethernet Switches-Release 1510
Chapter 1 802.1x Configuration Commands
Huawei Technologies Proprietary
1-19
ver-period
: Client-version-checking period timer, if within the period, no response
packet has been sent back from the supplicant system, the switch will resend the client
version checking request packet.
ver-period-value
: Value of the client-version-checking period timer, in seconds. This
value can range from 1 to 30 with a default value of 30.
Description
Use the
dot1x
timer
command to set a specified 802.1x timer.
Use the
undo dot1x
timer
command to resume the default value of a specified 802.1x
timer.
During an 802.1x authentication process, multiple timers are triggered to ensure that
the supplicant systems, the authenticator systems, and the Authentication servers
interact with each other in an arranged way. To make authentications being processed
in a desired way, you can use the
dot1x
timer
command to set values for these timers
as needed. This may be necessary in certain situations or for some tough network
environments. Normally, the defaults are recommended. (Note that some timers cannot
be adjusted.)
Related command:
display dot1x
.
Example
# Set the server-timeout to 150 seconds.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] dot1x timer server-timeout 150
1.1.14 dot1x version-check
Syntax
dot1x version-check
[
interface interface-list
]
undo dot1x version-check
[
interface interface-list
]
View
System view, Ethernet port view
Parameter
interface-list
: Ethernet port list. You can specify multiple Ethernet ports by providing this
argument in the form of
interface-list
= {
interface-name
[
to
interface-
name
] & < 1-10 >.
The
interface-name
argument is the port index of an Ethernet port and can be specified
in this form:
interface-name
= {
interface-type
interface-num
}, in which,
interface-type
specifies the type of a port and
interface-num
identifies the port number. Note that the
interface name
after the keyword
to
must have an
interface-num
that is greater than or