Command Manual - VLAN
Quidway S3500 Series Ethernet Switches
Chapter 3 GARP/GVRP Configuration Commands
Huawei Technologies Proprietary
3-3
Parameter
hold
: GARP Hold timer. After received certain registration information, the GARP
application entity will not send Join Message at once, instead, it starts the Hold timer.
All the registration information received within duration of the Hold timer will be
transmitted in the same frame after the Hold timer times out, thereby saving the
bandwidth resource.
join
: GARP Join timer. GARP application entity will send out Join message after the
Join timer goes timeout to make other GARP application entity register its own
information.
leave
: GARP Leave timer . When a GARP application entity wants to deregister certain
attribute information, it sends Leave message. The GARP application entity received
the message will starts Leave timer. If the entity receives no Join message before the
timer goes timeout, it will deregister the attribute information.
timer_value
: Value of GARP hold timer, join timer and leave timer in centisecond. The
step is 5 centiseconds. The range is according to the following rule: the value of Join
timer should be no less than the doubled value of Hold timer, and the value of Leave
timer should be greater than the doubled value of Join timer and smaller than the
Leaveall timer value, and the minimal value of Join timer is 10 centiseconds. By default,
Hold timer is 10 centiseconds, Join timer is 20 centiseconds, Leave timer is 60
centiseconds.
Description
Using
garp timer
command, you can configure GARP timer value. Using
undo garp
timer
command, you can restore the default value of GARP timer.
For the related command, see
display garp timer
.
Example
# Set Join timer of GARP as 300ms.
[Quidway-Ethernet0/1] garp timer join 30
3.1.4 garp timer leaveall
Syntax
garp timer leaveall timer_value
undo garp timer leaveall
View
System view