![Huawei Quidway S1700-24-AC Manual Download Page 209](http://html.mh-extra.com/html/huawei/quidway-s1700-24-ac/quidway-s1700-24-ac_manual_169458209.webp)
Indicators
NO TE
Hold down the mode switch button for 6s and release it to start the web initial login mode.
Either of the following situations will occur:
●
If the switch has no configuration file, the system attempts to enter the web initial
login mode. In this mode, the status of mode indicators is as follows:
●
If the system enters the web initial login mode successfully, all mode indicators
turn green and stay on for a maximum of 10 minutes.
●
If the system fails to enter the initial login mode, all mode indicators fast blink
for 10 seconds and then restore the default status.
●
If the switch has a configuration file, the system cannot enter the web initial login
mode. In this case, all mode indicators fast blink for 10s, and then return to the
default states.
Figure 5-42
Indicators on an S1730S-H24T4S-A
CloudEngine S1730S-H24T4S-A
PWR
SYS
SPEED
MODE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
GE
ETH
CONSOLE
28
ID
L/A
USB
RST
1
2
3
6
8 7
5
5
CloudEngine S1730S-H24T4S-A
PWR
SYS
SPEED
MODE
1
2
3
4
5
6
7
1
2
3
4
5
27
GE
ETH
CONSOLE
28
ID
L/A
USB
RST
6
8 7
5
Table 5-81
Description of indicators on an S1730S-H24T4S-A
No
.
Indic
ator
Name
Color
Statu
s
Description
1
PWR Power
indicator
-
Off
The switch is powered off.
Green
Stead
y on
The switch is powered on.
2
SYS
System
status
indicator
-
Off
The system is not running.
Green
Fast
blinki
ng
The system is starting.
Green
Stead
y on
In the system startup preparation
phase, the SYS indicator is steady
green for no more than 30 seconds.
S1700 Managed Series Ethernet Switches
Product Description
5 Hardware Structure
Issue 18 (2020-10-23)
Copyright © Huawei Technologies Co., Ltd.
175