LB is enabled to monitor the connectivity of an MPLS-TP link.
NOTE
If the network speed is rather slow,
timeout-value
(a parameter that specifies the period for waiting for a
response packet) can be set to a larger value when the
ping meg
command is configured.
----End
9.4.5 (Optional) Configuring Frame LM for a PW
This section describes how to configure single-ended or dual-ended frame loss measurement
(LM) to collect the reliability statistics of a pseudo wire (PW) built over a bidirectional label
switched path (LSP).
Context
Frame LM is a performance monitoring (PM) function provided by multiprotocol label switching
transport profile (MPLS-TP). Dual-ended frame LM is performed on the two maintenance entity
group end points (MEPs) of a PW. The measurement results are divided into near-end and far-
end frame loss:
l
Near-end frame loss: indicates the number and percentage of dropped frames that are sent
from a remote MEP (RMEP) to a MEP.
l
Far-end frame loss: indicates the number and percentage of dropped frames that are sent
from a MEP to an RMEP.
The NE80E/40E supports both single-ended and dual-ended frame LM functions. The
differences between them are listed in
Table 9-9
Differences between single-ended and dual-ended frame LM functions
Item
Single-ended Frame LM
Dual-ended Frame LM
Statistic
s display
Statistics can be displayed by
running either of the following
commands on a MEP:
l
Running the
lost-measure
single-ended
command displays
on-demand monitoring single-
ended frame loss statistics on the
device.
l
Running the
display mpls-tp
oam
meg
meg-name
statistic-
type
lost-measure
single-ended
command displays single-ended
frame loss statistics.
Running the
display mpls-tp oam
meg
meg-name
statistic-type
lost-measure
dual-ended
command on a MEP displays
dual-ended frame loss statistics.
Applicat
ion
scenario
On-demand monitoring
Proactive monitoring
Proactive monitoring
The procedure for configuring single-ended or dual-ended frame LM is as follows:
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
9 MPLS-TP OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
944