Figure 9-3
Networking diagram for sections on an LSP
Ingress LER
Transit LER
Transit LER
Egress LER
LSP
Maintenance End Point
Section
Table 9-3
MPLS-TP OAM functions supported by the NE80E/40E
Function
Application
Scenario
Configuration Procedure
Fault management
Connectivity check
: checks the continuous connectivity of
a section. If a link fault is detected, an alarm
will be generated and the link status of the
section will change to Down.
: checks the continuous connectivity of
a section at a specified time. Check results
will be directly displayed on a terminal.
: checks whether CC/CV configurations
on the two ends of a section are consistent
and will report alarms if any inconsistency
is detected.
Delay and delay
jitter measurement
: detects delay and delay jitters about a
section.
Pre-configuration Tasks
Before configuring MPLS-TP OAM for a section, complete the following task:
l
Setting up the sections on an LSP
Data Preparation
To configure MPLS-TP OAM for a section, you need the following data.
No.
Data
1
MEG name
2
Name of the tunnel interface bound to the ME
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
9 MPLS-TP OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
918