Current system time: 2010-08-30 18:02:12
Statistics last cleared:never
Last 300 seconds input rate 0 bytes/sec, 0 packets/sec
Last 300 seconds output rate 0 bytes/sec, 0 packets/sec
Input: 0 packets,0 bytes,
0 unicast,0 broadcast,0 multicast
0 errors,0 drops
Output:0 packets,0 bytes,
0 unicast,0 broadcast,0 multicast
0 errors,0 drops
----End
Configuration Files
l
Configuration file of Router A
#
sysname RouterA
#
bfd
#
interface GigabitEthernet1/0/0
undo shutdown
ip address 10.1.1.1 255.255.255.0
#
interface GigabitEthernet1/0/0.1
undo shutdown
vlan-type dot1q 10
ip address 10.2.1.1 255.255.255.0
#
bfd atob bind peer-ip default-ip interface GigabitEthernet1/0/0
discriminator local 10
discriminator remote 20
process-interface-status sub-if
commit
#
return
l
Configuration file of Router B
#
sysname RouterB
#
bfd
#
interface GigabitEthernet1/0/0
undo shutdown
ip address 10.2.1.2 255.255.255.0
#
interface GigabitEthernet1/0/0.1
undo shutdown
vlan-type dot1q 10
ip address 10.1.1.2 255.255.255.0
#
bfd btoa bind peer-ip default-ip interface GigabitEthernet1/0/0
discriminator local 20
discriminator remote 10
process-interface-status sub-if
commit
#
return
5.17.9 Example for Configuring Multi-Hop BFD
This example shows how to configure a BFD session on both ends of a multi-hop path to fast
detect faults on the multi-hop path.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
5 BFD Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
405