![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 383](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453383.webp)
Procedure
l
Run the
display bfd configuration
{
all
|
static
[
name
bfd-name
] |
discriminator
local-
discr-value
|
dynamic
|
peer-ip
peer-ip
[
vpn-instance
vpn-instance-name
] } [
verbose
]
command in any view to check BFD configurations.
l
Run the
display bfd configuration
{
all
|
static
|
peer-ipv6
peer-ipv6
[
vpn-instance
vpn-
instance-name
] } [
verbose
] command in any view to check BFD6 configurations.
l
Run the
display bfd interface
[
interface-type
interface-number
] command in any view
to check information about an interface enabled with BFD.
l
Run the
display
bfd
session
{
all
|
static
|
dynamic
|
discriminator
discr-value
|
peer-ip
peer-ip
[
vpn-instance
vpn-instance-name
] } [
verbose
] [
slot
slot-id
] command in any
view to check information about a BFD session.
l
Run the
display bfd session
{
all
|
static
|
peer-ipv6
peer-ipv6
[ ] } [
verbose
] [
slot
slot-
id
] command in any view to check information about a BFD6 session.
l
Run the
display bfd statistics
[
slot
slot-id
] command in any view to check statistics about
global BFD.
l
Run the
display bfd statistics session
{
all
|
static
|
dynamic
|
discriminator
discr-
value
|
peer-ip
peer-ip
[
vpn-instance
vpn-instance-name
] } [
slot
slot-id
] command in
any view to check statistics about a BFD session.
l
Run the
display bfd statistics session
{
all
|
static
|
peer-ipv6
peer-ipv6
[ ] } [
slot
slot-
id
] command in any view to check statistics about a BFD6 session.
----End
5.17 Configuration Examples
The following sections provide several examples for configuring fast BFD link detection. Each
configuration example consists of the networking requirements, configuration roadmap,
configuration procedures, and configuration files.
Context
NOTE
In this example, interface numbers and link types on the NE40E-X8 are used. On existing networks, the
interface numbers and link types are different from those used in this example.
5.17.1 Example for Configuring Single-hop BFD for a Layer 3
Physical Link
In this example, a single-hop BFD session for detecting faults in a Layer 3 physical link is
configured to rapidly check a direct link on a network.
Networking Requirements
NOTE
POS interfaces cannot be configured on the -X1 or -X2 models of NE80E/40Es.
On the network shown in
, BFD in asynchronous mode is used to detect a directly
connected link between Router A and Router B.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
5 BFD Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
366