Table 1-16
Frequency information of the 26 GHz frequency band (SP ODU)
T/R
Spacing
(MHz)
Sub-band
Lower Sub-band Tx
Frequency (MHz)
Higher Sub-band Tx
Frequency (MHz)
Lower
Limit
Upper
Limit
Lower
Limit
Upper
Limit
1008
A
24,549.00
24,885.00
25,557.00
25,893.00
1008
B
24,829.00
25,165.00
25,837.00
26,173.00
1008
C
25,109.00
25,445.00
26,117.00
26,453.00
Table 1-17
Frequency information of the 38 GHz frequency band (SP ODU)
T/R
Spacing
(MHz)
Sub-band
Lower Sub-band Tx
Frequency (MHz)
Higher Sub-band Tx
Frequency (MHz)
Lower
Limit
Upper
Limit
Lower
Limit
Upper
Limit
700
A
38,595.00
38,805.00
39,295.00
39,505.00
700
B
38,795.00
39,005.00
39,495.00
39,705.00
700
C
38,995.00
39,205.00
39,695.00
39,905.00
700
D
39,195.00
39,405.00
39,895.00
40,105.00
1260
A
37,044.00
37,632.00
38,304.00
38,892.00
1260
B
37,604.00
38,192.00
38,864.00
39,452.00
1.7.2 SPA ODU
The SPA ODU is a type of the standard power ODU.
Modulation Mode
Table 1-18
Modulation Mode (SPA ODU)
Item
Performance
Modulation
mode
QPSK/16QAM/32QAM/64QAM/128QAM
Channel
Spacing
3.5/7/14/28 MHz
1 ODU
OptiX RTN 600 ODU
Hardware Description
1-16
Huawei Proprietary and Confidential