Values
Value Range
Default Value
SA4, SA5, SA6, SA7, SA8,
All versions
All versions
The following table lists the description of each value.
Value
Description
SA4
Indicates that the S1 byte is transmitted through the SA4
timeslot of the external clock port.
SA5
Indicates that the S1 byte is transmitted through the SA5
timeslot of the external clock interface.
SA6
Indicates that the S1 byte is transmitted through the SA6
timeslot of the external clock interface.
SA7
Indicates that the S1 byte is transmitted through the SA7
timeslot of the external clock interface.
SA8
Indicates that the S1 byte is transmitted through the SA8
timeslot of the external clock interface.
All versions
Indicates that the S1 byte is transmitted through all timeslots
of the external clock interface.
Configuration Guidelines
None.
Relationship with Other Parameters
This parameter can be set only when the
External Clock Output Mode
parameter is set to
2
Mbit/s
.
Related Information
None.
7.115 External Source Output Threshold
Description
The
External Source Output Threshold
parameter is used to set the output quality threshold
of the external clock source. When the output quality of the external clock source is inferior to
the threshold, the action specified for 2M phase-locked source failure is invoked to control the
external clock source output.