7.41 Error Frame Monitor Window (ms)
Description
The
Error Frame Monitor Window (ms)
parameter specifies the period during which the
number of error frames received at the port exceeds the specified upper threshold. In this case,
a link event alarm is reported.
Impact on the System
After you set the
Error Frame Monitor Threshold (Entries)
and
Error Frame Monitor
Window (ms)
parameters, a link event alarm is reported if the actual number of error frames in
the link exceeds the specified threshold.
Values
Valid Values
Default Value
Unit
1000-60000, in step length of 100
1000
ms
Configuration Guidelines
Set the value according to the actual port rate and the monitoring period.
Make sure that the value of
Error Frame Monitor Threshold (Entries)
is not greater than the
maximum number of frames received at the port within the time specified in
Error Frame
Monitor Window (ms)
.
Relationship with Other Parameters
To set
Error Frame Monitor Window (ms)
, set
Error Frame Monitor Threshold
(Entries)
. Moreover, set
Port Rate
. For details, refer to the description of the
Error Frame
Period Window(Frames)
parameter.
7.42 Error Frame Monitor Threshold(Entries)
Description
The
Error Frame Monitor Threshold(Entries)
parameter specifies the upper threshold of error
frames received at the port. In this case, a link event alarm is reported.
Impact on the System
After you set the
Error Frame Monitor Threshold(Entries)
and
Error Frame Monitor
Window (ms)
parameters, a link event alarm is reported if the actual number of error frames in
the link exceeds the specified threshold.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
7 List of Parameters
Issue 02 (2011-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7-39