User
Paramete
r
Value in
This
Example
Description
Sink VC4
VC4-1
In this example, VC4-1 is specified as the
VC-4 timeslot of the Ethernet service on the
line board.
Sink
Timeslot
Range(e.g.
1,3-6)
1-30
The value range of the sink timeslots can be
the same as or different from the value
range of the source timeslots. The number
of source timeslots must be, however, the
same as the number of sink timeslots.
Activate
Immediatel
y
Yes
-
Step 2
Configure the EPL services on NE2 and NE4.
NOTE
The Ethernet services of NE2 and NE4 are point-to-point transparent transmission services. See
Configuring EPL Services on an Ethernet Transparent Transmission Board
Step 3
Enable the performance monitoring function of the NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 4
Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Relevant Task
If the services are configured incorrectly and thus need to be deleted, see Deleting SDH Services.
4.11 Ethernet Port Configuration Parameters
Before configuring an Ethernet service, you need to configure the corresponding Ethernet ports.
4 Configuring Ethernet Services
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
4-130
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2011-06-30)