Bracket to Be Adjusted
Parameter to Be
Adjusted
Default value (dB)
ATT0
Level of combined CATV
and downstream DOCSIS
signal of the RF OUT0.
4
ATT1
Level of combined CATV
and downstream DOCSIS
signal of the RF OUT1.
4
ATT2
Level of combined CATV
and downstream DOCSIS
signal of the RF OUT2.
4
ATT3
Level of combined CATV
and downstream DOCSIS
signal of the RF OUT3.
4
No.
Test point
Function
TP.1
Tests level of the RF OUT0
port signal.
TP.8
Tests level of the RF OUT1
port signal.
TP.9
Tests level of the RF OUT2
port signal.
TP.4
Tests level of the RF OUT3
port signal.
TP.7
Tests level of combined
CATV and downstream
DOCSIS signals. (Main)
5.3 Adjusting the Upstream DOCSIS Signal Level
Step 1
Confirm the CM-side output level of the RF OUT port and record it as A. Run the
display
cable modem extended-tx-power
command to query
Extended US TX Power
. A =
Upstream TX Power - cable line attenuation.
Step 2
Run the
cable upstream
command to configure the upstream receive level of DOCSIS
module (B). The default value is 6 dBmV.
Step 3
Input single-tone signals (20 MHz and 40 MHz) into the test points of the RF OUT port,
respectively. Set the signal level to A+20 dBuV.
MA5833-DD60
Hardware Commissioning Guide
5 Adjusting the Signal Level
Issue 01 (2018-12-26)