Table 2-4 describes the RHUB3908 indicators.
Table 2-4
RHUB3908 indicators
Indicator
Color
Status
Description
RUN
Green
Steady on
There is power supply, but the RHUB is
faulty.
Steady off
There is no power supply, or the RHUB is
faulty.
Blinking on for
1s and off for 1s
The RHUB is functioning properly.
Blinking on for
0.125s and off
for 0.125s
The RHUB is loading software,
configuring data, not working, or the
software is in security version.
ALM
Red
Steady on
Alarms have been generated, and the
device must be replaced.
Steady off
No alarms have been generated.
Blinking on for
1s and off for 1s
At least one alarm has been reported. The
RHUB may have to be replaced.
ACT
Green
Steady on
The RHUB is activated and functioning
normally.
Steady off
The RHUB is not activated.
Blinking on for
1s and off for 1s
The device is under commissioning.
CPRI0/CPRI
1
Red or
green
Steady green
The CPRI link is functioning properly.
Steady red
An optical module has failed to transmit or
receive signals because the optical module
is faulty or the optical fiber is broken.
Blinking red on
for 1s and off for
1s (red)
The CPRI link is out of lock possibly
because the dual-mode clock sources are
not synchronous or the data rates over
CPRI ports do not match.
Steady off
The optical module is not detected or is
powered off.
GE0/1
This indicator
is on
only when the
PHS feature
is enabled.
Green
Steady on
The connection is set up.
Steady off
No connection is detected.
Yellow
Blinks
Data has been transmitted or received.
Steady off
No data has been transmitted or received.
PWR0~7
Yellow
Steady on
The RHUB is supplying power to the
pRRU properly.