NOTE
l
The PTZ parameters configured on the IPC must be the same as those configured on the external PTZ.
Otherwise, the PTZ functionality may not work properly.
l
The
Enable
in the transparent channel and
Enable serial port
in the PTZ parameters area cannot be
selected at the same time.
Table 8-2
Parameter description
Parameter
Description
PTZ ID
Unique ID of the PTZ.
Enable serial port
Indicates whether to enable the serial port.
Serial port ID
The same as the PTZ serial port number.
PTZ protocol
The same as the PTZ protocol.
PTZ address
The same as the PTZ address.
Direction control
Enables forward or backward PTZ control:
l
Forward
Enables the forward control of the PTZ. For example, if
you click the left button, the PTZ moves leftward.
l
Backward
Enables the backward control of the PTZ. For example, if
you click the left button, the PTZ moves rightward.
Wiper linkage switch
output 1
Indicates whether to enable the wiper linkage switch output
1.
NOTE
l
To use the rain wiper that is controlled by the Boolean value,
connect the rain wiper to Boolean value output 1 and enable this
function.
l
You cannot enable this function if Boolean value output 1
connects to an alarm device.
l
If this function is disabled, the rain wiper button is unavailable.
Step 3
Click
Save
.
----End
8.2 Setting Preset Position Parameters
After a preset position is configured, you can quickly rotate the IPC to the required position.
You can add, modify, and delete preset positions. A maximum of 256 preset positions can be
added for an IPC.
Context
The IPC's horizontal shooting angle, vertical shooting angle, and zoom times can be stored as
a preset position. The preset position can be numbered.
IPC6125-WDL-FA
Configuration Guide
8 Setting PTZ Control Parameters
Issue 01 (2016-08-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
95