Chapter 7 Maintaining System
7-52
7.5.4 Showing Alarm Configuration Information
In IAD108, an alarm has the following attributes: alarm ID, alarm
name, alarm level, default alarm level, alarm type, alarm class,
command line output flag, statistics flag, number of parameters,
15-minute threshold, 24-hour threshold, and detailed alarm
explanation.
You can query the alarm attribute through the command below.
show alarm content
alarmid
alarmid
: Alarm ID
7.5.5 Setting Alarm Output to Command Line
Terminal
After generated by the system, all the alarms will be reported to
the command line terminal by default. However, due to different
requirements and concerns by the users, IAD108 provides the alarm
output mask function. You can set whether export the alarms to
command line by alarm ID, alarm level, alarm type, and all alarms.