If the VMD function is disabled, NVMe drives support only orderly hot swap.
Table 5-10 NVMe drive indicators (VMD disabled)
Activity
Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive cannot be detected.
Steady on
Off
The NVMe drive is working properly.
Blinking at 2 Hz
Off
Data is being read from or written
to the NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located or
hot-swapped.
Off
Blinking at 0.5
Hz
The hot removal process is
complete, and the NVMe drive is
removable.
Steady on/Off
Steady on
The NVMe drive is faulty.
5.5.4 RAID Controller Card
The RAID controller card supports RAID configuration, RAID level migration, and
drive roaming.
●
PCIe plug-in RAID controller cards and screw-in RAID controller cards are
supported.
●
Contact your local Huawei sales representative or use the
Computing Compatibility Checker
to determine the components to be used.
●
For details about the RAID controller card, see
.
5.6 Network
5.6.1 LOMs
LOMs provide network expansion capabilities.
Table 5-11 LOMs supported by the 2288X V5
NIC Type Chip
Model
Port
Type
Number
of Ports
NC-SI
WOL
PXE
LOM
X722
10GE
optical
port
2
√
√
√
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper
5 Hardware Description
Issue 03 (2020-04-20)
Copyright © Huawei Technologies Co., Ltd.
37