7.2.4.1 Installing L-Shaped Guide Rails
L-shaped guide rails are designed for Huawei cabinets only.
The 2288H V5 servers are stackable onto L-shaped guide rails.
Procedure
Step 1
Install floating nuts.
1.
Determine the installation positions of the floating nuts according to the cabinet device
installation plan.
Figure 7-3
Spacing of 1U on a mounting bar of a cabinet
–
Floating nuts are used to tighten screws.
–
The boundary between Us is used as the reference for calculating device installation space.
2.
Fasten the lower end of a floating nut to the target square hole in a mounting bar at the
front of the cabinet.
3.
Use a floating nut hook to pull the upper end of the floating nut, and fasten it to the upper
edge of the square hole.