Parameter
Parameter
Description
Frame
Subrack number of the EDFA
Slot
Slot number of the EDFA
Fan current
temperature
Actual fan temperature
Impact on the System
The EDFA temperature rises and its service life is affected.
Possible Cause
The ambient temperature is excessively high.
Handling Procedure
Decrease the ambient temperature.
Alarm Clearing Condition
When the fan temperature drops below 78°C, the alarm is cleared.
2.3.5 Power Supply Alarms
2.3.5.1 ALM-4100 Power Supply Out of range Alarm
Description
When the internal power voltage of the device is higher than 14 V or lower than 10 V, this
alarm is generated.
Attribute
Alarm ID
Alarm Severity
Alarm Type
4100
Major
Fault alarm
Parameter
Parameter
Description
Frame
Subrack number of the EDFA
EDFA0820-D
Routine Maintenance Guide
2 Common Alarm Handling