Attribute
Alarm ID
Alarm Severity
Alarm Type
65539
Major
Fault alarm
Parameter
Parameter
Description
Frame
Subrack number of the EDFA
Slot
Slot number of the EDFA
PUMP
PUMP ID. Value: 1
the pump current
Actual current of EDFA PUMP1
Impact on the System
The EDFA service life is affected.
Possible Cause
The current in PUMP1 exceeds the current alarm threshold.
Handling Procedure
Check whether the current alarm threshold is set to a proper value. If it is set to a proper
value, contact Huawei.
Alarm Clearing Condition
When the current of EDFA PUMP1 drops below the preset alarm threshold, the alarm is
cleared.
2.3.3.2 ALM-65540 EDFA PUMP1 Temperature Alarm
Description
The temperature of PUMP1 exceeds the upper threshold.
The temperature of PUMP1 is below the lower threshold.
Alarms are generated for both scenarios.
EDFA0820-D
Routine Maintenance Guide
2 Common Alarm Handling
Issue 02 (2018-07-02)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
14