Table 2-11
Indicators on the fan module
Indicator
Description
FAN indicator
If the indicator is steady green, it indicates that the fan module works
normally.
The indicator is off when the fan module is unregistered, powered
off, or has a hardware fault.
If the indicator is steady red, it indicates that the fan module fails.
2.4 Data Plane
2.4.1 Introduction to the Data Plane
NPUs are key parts on the CX600-X2-M8 and are responsible for network processing and data
exchange between PICs and NPU-50s.
The procedure for data processing is as follows:
1.
The IP packets sent from PICs and NPU converge at a convergence module.
2.
The NP processes the IP packets.
3.
The TM module performs traffic management on the IP packets.
Figure 2-15
Data plane architecture of the CX600-X2-M8
B
ac
kp
la
ne
P
H
Y
SFP
RJ45
INTERFACE
CONVERSION
MODULE
P
H
Y
SFP
RJ45
INTERFACE
CONVERSION
MODULE
OVER
SUBSCRI
BED
NP
TM
NPU
OVER
SUBSCRI
BED
NP
TM
NPU
2.4.2 Introduction to the NPU-50
NOTE
NPU-50 must not be installed in an outdoor cabinet.
HUAWEI CX600-X1-M/CX600-X2-M Series Metro
Services Platform
Hardware Description
2 CX600-X2-M8 Hardware Description