l
If the
MGMT
port on the active MM910 is already connected with a network cable, do
not remove the network cable from the
MGMT
port. Otherwise, an active/standby
switchover of the MM910s will be triggered, which may cause network interruption.
l
If you want to connect your local PC directly to the MM910 using a network cable but the
MGMT
port on the active MM910 is already connected with a network cable, connect the
network cable from the local PC to the
STACK
port of the active MM910 in the chassis. If
the
STACK
port on the active MM910 is also used, connect the network cable to an idle
STACK port on an active MM910 in a chassis cascaded with the E9000 chassis.
Step 2
Use an SSH connection tool to log in to the MM910 CLI by using the floating IP address of
the MM910s.
This topic describes how to use PuTTY to log in over SSH. For details, see
the MM910 CLI Over a Network Port by Using PuTTY
Step 3
Log in to the CLI of a switching plane over MM910 SOL.
6.1 Logging In to or a Switch Module over MM910 SOL
.
----End
l
Log in to the CLI of a switching plane over a serial port.
Step 1
Use a DB9-RJ45 cable to connect the RS232 serial port of the PC to the
SYS
serial port on
the CX320 panel.
Step 2
Use a serial port communication tool to log in to the CLI of a switching plane.
Set the key communication parameters as follows:
l
Serial line to connect to
:
COMn
l
Speed (baud)
:
115200
l
Data bits
:
8
l
Stop bits
:
1
l
Parity
:
None
l
Flow control
:
None
NOTE
n
indicates the serial port number and is an integer.
In this document, PuTTY is used as an example for login over a serial port. For details, see
6.3 Logging In to a Device Over a Serial Port by Using PuTTY
.
----End
4.5 Checking the Switching Plane
Check the converged switching plane operating status of the CX320.
CX320 Switch Module
User Guide
4 Configuring the CX320