4.1 List of BBU3900 Cables
This describes the BBU3900 cables. The cables are the PGND cable, BBU power cable, E1/T1
cable, E1/T1 surge protection transfer cable, FE/GE cable, FE/GE surge protection transfer
cable, Iub optical cable, CPRI optical cable, APMI-BBU monitoring signal cable, BBU alarm
cable, EMUA monitoring signal cable, Monitoring signal cable for the HEUA and GPS clock
signal cable.
lists the BBU3900 cables.
Table 4-1
List of BBU3900 Cables
Cable
One End
The Other End
Connector
Installation
Position
Connector
Installation
Position
OT terminal
(6mm
2
, M4)
BBU/Grounding
bolt
OT terminal
(6mm
2
, M8)
Nearest
grounding bar
3V3 connector
BBU/UPEU/
PWR
OT terminal
(6mm
2
, M4)
DCDU/LOAD6
3V3 connector
BBU/UPEU/
PWR
H4 connector
AC/DC power
eqiupment/
LOAD1
3V3 connector
BBU/UPEU/
PWR
Easy Power
Receptacle
(Pressfit Type)
Connector
EPS/LOAD1
DB26 connector
BBU/UELP or
WMPT/E1/T1
port
The connector
needs to be made
on site according
to the field
requirements.
Port on the
transmission
device
4.6 E1/T1
Surge
Protection
Transfer
Cable
DB26 connector
BBU/WMPT/
E1/T1 port
DB25 connector
BBU/UELP/
INSIDE
RJ-45 connector
BBU/UFLP/
FE0 port at the
OUTSIDE side
BBU/WMPT/
FE0
RJ-45 connector
Port on the
transmission
device
BBU3900
Hardware Description
4 BBU3900 Cables
Issue 11 (2010-11-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4-3