![Huawei AR2200 Series Configuration Manual Download Page 85](http://html.mh-extra.com/html/huawei/ar2200-series/ar2200-series_configuration-manual_169296085.webp)
Data Preparations
Before performing operations after login, you need the following data:
No.
Data
1
Password used for switching user levels
2
Type and number of the user interface
3
Contents of the message to be sent
5.5.2 Switching User Levels
If a user wants to upgrade from a lower level to a higher level after logging in to the router, a
password is required. The password needs to be configured in advance.
Context
To prevent an unauthorized user from using high-level commands, a password is required to
increase the user level.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
super password
[
level
user-level
] {
simple
|
cipher
}
password
The password for switching user levels is configured.
By default, the password for the user is set to Level 3.
CAUTION
If
simple
is configured, the password is saved in the configuration file in plain text. This means
that low-level login users can easily obtain and change the password by checking the
configuration file, compromising the network security. Therefore, selecting
cipher
to save the
password in the cipher text is recommended.
If
cipher
is used to set the password, the password cannot be obtained from the system. Save
the password to avoid oblivion or missing.
Step 3
Run:
quit
Return to the user view.
Step 4
Run:
Huawei AR2200 Series Enterprise Routers
Configuration Guide - Basic Configuration
5 Configuring User Login
Issue 02 (2011-10-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
74