5.1 On-site Cable Assembly and Installation
5.1.1 Cable Assembly Precautions
Checking the Appearance of Cables
l
If the cable jacket or insulation is visibly dirty, clean it before assembly.
l
If the jacket or insulation of a cable has visible damage, irreparable scuffing, or other
defects, do not use the cable.
l
If the shield layer of a cable is damaged, do not use the cable.
l
If the cable jacket or insulation cracks after the cable is bent or twisted, discard this cable
and check whether other cables have the same problem. If other cables have the same
problem, replace these cables.
Checking the Appearance of Connectors
l
Do not use connectors with visible defects, damage, rust or scuffing.
l
Do not use connectors if their shells or pins have exposed part or uneven plating, or their
pins are lost, broken, or bent.
l
Do not use connectors that have dirt on their pins or in their jacks or if there are
conductors between pins or between pins and the shell.
Precautions for Assembly
l
Use dedicated tools or tools delivered by Huawei and follow the methods given here
during assembly.
l
Hold terminals of cables instead of pulling the cables themselves when installing or
removing cable components.
l
Take the following precautions when cutting or stripping cables:
–
Make cables slightly longer than necessary.
–
Coil cables longer than 2 m (6.56 ft) after cutting. Bind and fasten the coils using
bundling ropes. The inner diameters of the coils should be larger than 20 times the
outer diameters of the cables.
–
When stripping the jackets of cables, avoid damaging the shield layers (braid or
aluminum foil), insulation, core conductors, and other jackets that do not need to be
stripped.
–
After assembling cables, cut all visible cross sections of jackets to ensure that the
cross sections are arranged neatly.
–
Do not touch the core conductors of cables with your hands. Terminate exposed
conductors in a timely way after stripping off insulation so that the surface of the
conductors does not become oxidized.
l
Take the following precautions when crimping and connecting cables or connectors:
–
The terminals and conductors should be connected tightly after they are crimped.
They should not be moved or turned.
R250D
Hardware Installation and Maintenance Guide
5 Appendix
Issue 01 (2016-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
22