No
.
Procedu
re
Description
Standards for Continuing the
Commissioning
If one cell is serviceable, the
detection succeeds. Otherwise,
the software commissioning
persists, and the system displays
a message, indicating that no cell
is serviceable.
5
Automati
cally
verify
services
The M2000 automatically collects
the performance counters related to
GBTS CS and PS services and
checks that the GBTS services are
normal. The involved performance
counters are as follows:
l
CS services:
SDCCH
Verification
and
TCH
Verification
l
PS services:
Uplink GPRS
Verification
and
Downlink
GPRS Verification
You can set the M2000 to skip the
service verification when starting
the commissioning task.
If each performance counter is once
displayed as a value that is not
0
, the
service verification succeeds and
the commissioning switches to the
Confirming completed
status.
Otherwise, the service verification
persists.
6
Complete
the
commissi
oning
When the commissioning switches
to the
Confirming completed
status, you need to confirm the
completion of the GBTS
commissioning. After the
commissioning is complete, the
M2000 automatically restores the
GBTS status to normal status so that
the GBTS alarms can be monitored
normally.
Not involved.
5.4.2 Procedure for Automatically Commissioning the NodeB by
the M2000
The procedure for automatically commissioning the NodeB by the M2000 involves detecting
the OM channel, upgrading the software and configuration, monitoring the software
commissioning, and verifying the services.
For details on the NodeB commissioning procedure, see
.
5 Commissioning the MBTS in GL or UL Mode on the
M2000
3900 Series Multi-Mode Base Station
Commissioning Guide
5-22
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2010-07-30)