5.4.1 Procedure for Automatically Commissioning the GBTS by the
M2000
This section describes the process of automatic GBTS commissioning performed by the
M2000.
describes the process of automatic GBTS commissioning. After the automatic
software commissioning starts, you can manually complete the commissioning according to the
actual requirement. For details, see
5.11.1 Confirming a GBTS Commissioning Task
.
Table 5-1
Process of automatic GBTS commissioning
No
.
Procedu
re
Description
Standards for Continuing the
Commissioning
1
Automati
cally set
the
maintena
nce mode
of the
GBTS
After locating the GBTS, the
M2000 automatically sets the
maintenance mode of the GBTS to
testing so that all alarms reported by
the GBTS during the
commissioning are not to be
displayed on the M2000 alarm
interface by default. This avoids the
alarms from affecting normal
network monitoring.
You can use the monitoring
function provided by the GBTS
commissioning to query all alarms
generated during the GBTS
commissioning. For details, see
5.5.1 Viewing the GBTS Alarm
Status
.
Regardless of whether the
maintenance mode of the GBTS is
set successfully, the M2000
automatically proceeds with the
next procedure.
5 Commissioning the MBTS in GL or UL Mode on the
M2000
3900 Series Multi-Mode Base Station
Commissioning Guide
5-18
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 02 (2010-07-30)