Table 5-3 Operating temperature limitations
Model
Max. 30°C
(86°F)
Max. 35°C (95°F)
(ASHRAE Class A2
Compliant)
Max. 40°C (104°F)
(ASHRAE Class A3
Compliant)
EXP model
with 12 x
3.5-inch
drives
Supports all
configurations
.
Supports all
configurations.
● Does not support 64-
core CPUs.
● Does not support PCIe
SSD cards
● Does not support
passive cooling GPUs
(including DMINI
cards).
● Does not support rear
drives
NOTE
If one fan fails, the highest operating temperature of the server is 5°C (9°F) lower than that
in normal cases.
5.3 Physical Specifications
Table 5-4 Physical specifications
Item
Description
Dimensio
ns (H x
W x D)
Chassis with 3.5-inch drives: 86.1 mm (2U) x 447 mm x 790 mm
(3.39 in. x 17.60 in. x 31.10 in.)
Installati
on space
Requirements for cabinet installation (cabinet compliant with the
International Electrotechnical Commission (IEC) 297 standard):
● Cabinet width: 482.6 mm (19 in.)
● Cabinet depth: ≥ 1000 mm (39.37 in.)
Requirements for guide rail installation:
● L-shaped guide rails: apply only to Huawei cabinets.
● Adjustable guide rails: apply to a cabinet with a distance of 543.5
mm to 848.5 mm (21.40 in. to 33.41 in.) between the front and
rear mounting bars.
Weight
in full
configura
tion
Net weight:
Server with 12 x 3.5-inch front 2 x 3.5-inch rear 2 x
2.5-inch rear drives: 30 kg (66.15 lb)
Packaging materials: 5 kg (11.03 lb)
TaiShan 200 Server
White Paper (Model 2180)
5 Product Specifications
Issue 02 (2020-06-22)
Copyright © Huawei Technologies Co., Ltd.
24