OWNER’S AND  

INSTALLATION MANUAL

SWIMMING POOL HEAT PUMP

ENGLIS

H

Thanks for choosing our product.  

Please, read carefully this manual 

before using the product. 

LION

HTW-SWP-O-070LIO | HTW-SWP-O-110LIO 

HTW-SWP-O-160LIO | HTW-SWP-O-190LIO

Summary of Contents for LION HTW-SWP-O-070LIO

Page 1: ...STALLATION MANUAL SWIMMING POOL HEAT PUMP ENGLISH Thanks for choosing our product Please read carefully this manual before using the product LION HTW SWP O 070LIO HTW SWP O 110LIO HTW SWP O 160LIO HTW...

Page 2: ......

Page 3: ...ation Instruction Interface display Key and icon function instruction Startup shutdown 4 4 Switch Mode Clock setting Mute setting Keyboard lock Fault interface 5 Maintenance and Inspection 6 Appendix...

Page 4: ...type unit The indoor unit can be Discretely hidden or semi hidden to suit a luxury house Our heat pump has following characteristics 1 Durable The heat exchanger is made of PVC Titanium tube which ca...

Page 5: ...er The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Appl...

Page 6: ...eparately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Directive 2002 95 EC RoHs T...

Page 7: ...0Hz Rated 90Hz Rated 90Hz Rated Heating Capacity 90Hz Rated 90Hz Rated 90Hz See the drawing of the units See package lable see nameplate see package label HTW SWP O 110LIO 11 66 39644 1 97 11 66 6698...

Page 8: ...ated 90Hz Rated 90Hz Rated Heating Capacity 90Hz Rated 90Hz Rated 90Hz Rated Heating Outdoor air temp 27 C Outdoor air temp 15 C Inlet Outlet water temp 26 C 28 C Inlet Outlet water temp 26 C 28 C Dur...

Page 9: ...110LIO unit mm 2 2 Dimensions for Swimming Pool Heat Pump Unit Model HTW SWP O 160LIO HTW SWP O 190LIO unit mm Water outlet 50 Water inlet 50 1002 190 1035 395 201 610 103 350 770 Water outlet 50 Wat...

Page 10: ...ion Please follow these steps when using for the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valve and start the un...

Page 11: ...of a continuous source of fresh air which reduces it efficiency and may prevent adequate heat delivery Normally the pool heat pump is installed within 7 5 metres of the pool The longer the distance f...

Page 12: ...o the basepan and drain out through the barbed plastic condensation drain fitting on the side of the basepan This fitting is designed to accept 20mm clear vinyl tubing which can be pushed on by hand a...

Page 13: ...e no effect on the 3 minute countdown 3 5 Swimming Pool Heat Pumps Electrical Wiring NOTE Although the unit heat exchanger is electrically isolated from the rest of the unit it simply prevents the flo...

Page 14: ...sed to enter and exit the mute mode with one click 4 2 Key and icon function instruction Key symbols It is used to switch the unit mode temperature setting and parameter setting It is used to carry ou...

Page 15: ...f the unit It will display when compressor is started It will display when water pump is started It will display when fan is started When the timing mute function is started it keeps bright for a long...

Page 16: ...shut down the wire controller will display as follows Operations are the same as under ON OFF main interface Under the main interface Short press to switch the unit among heating cooling and automatic...

Page 17: ...eping consistent with the mode before defrosting Notes During the defrosting mode switch is available And when switching the mode the unit won t work under a new mode until defrosting is completed Hea...

Page 18: ...ay the clock key permanently Under the clock setting interface if short press the change will not be saved and return to the main interface if there is no operation for 20s the system will automatical...

Page 19: ...ving timing On1 Short press and at the sametime Short press for saving the change and returning to the main interface Flashing Short press for cancelling timing setting Notes If there is no operation...

Page 20: ...mute Keep long press of fo r 2 s Short press or Short press for entering the hour digit setting of timing on mute Short press or Short press for confirming the timing on mute and turn to the setting o...

Page 21: ...terface When the unit fails the wire controller can display the corresponding code according to the fault reason Refer to the fault table for the specific definition of the fault codes 2 Two or more f...

Page 22: ...sor is broken or short circuit The temp Sensor is broken or short circuit The temp Sensor is broken or short circuit The temp Sensor is broken or short circuit The environment temp is low The ambient...

Page 23: ...rsion board hardware Check whether current return wires connected motor Check and adjust the current measurement Check the input voltage measurement Check the input voltage measurement Check the input...

Page 24: ...truction 4 10 2 Parameter list Meaning 27 C 27 C 27 C Remarks Adjustable Adjustable Adjustable Default Refrigeration target temperature set point Heating the target temperature set point Automatic tar...

Page 25: ...onnection often Should the unit begin to operate abnormally switch it off and contact the qualified technician Discharge all water in the water pump and water system so that freezing of the water in t...

Page 26: ...temperature input Mode Switch input Master slave machine switch Antifreeze temperature input System Exhaust temperature input Compressor current detection Pressure Sensor input OUT1 OUT2 OUT4 OUT5 AC...

Page 27: ...and AI DI11 port is used as master slave switch by default when the unit uses non EC fan PWM IN port is used as master slave switch by default and AI DI11 port is used as anti freezing protection swit...

Page 28: ...nd of its useful life must be handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent...

Page 29: ...line MCB Creepage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 16mm...

Page 30: ...Note...

Page 31: ...Note...

Page 32: ...revent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainablereuse of material resources To return your used device please...

Page 33: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 93 390 42 20 Fax 93 390 42 05 info htwspain com...