HTW HTWS026IX80SR32-I Owners And Installation Manual Download Page 17

15

Installation prepare

1 Level meter

2 Screw driver

3 Impact drill

4 Drill head

5 Pipe expander

6 Torque wrench

7 Open-end wrench

8 Pipe cutter

9 Leakage detector

10 Vacuum pump

11 Pressure meter

12 Universal meter

13 Inner hexagon spanner

14 Measuring tape

Tools

Safety precaution

1. Must follow the electric safety regulations when installing the unit.

2. According to the local safety regulations, use qualified power supply circuit and circuit

break.

3. Make sure the power supply matches with the requirement of air conditioner. Unstable

power supply or incorrect wiring or malfunction. Please install proper power supply cables
before using the air conditioner.

4. Properly connect the live wire, neutral wire and grounding wire of power socket.

5. Be sure to cut off the power supply before proceeding any work related to  electricity and

safety.

6. Do not connect the power before finishing inatallation.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent

or similarly qualified persons in order to avoid a hazard.

8. The temperature of refrigerant circuit will be high, please keep the interconnection cable

away from the copper tube.

9. The appliance shall be installed in accordance with national wiring regulations.

10. Installation must be performed in accordance with the requirement of NEC and CEC by

authorized personnel only.

11. Appliance shall be installed, operated and stored in a room with a floor area larger than

“X”m

2

  (see table 1).

Please notice that the unit is filled with flammable gas R32. Inappropriate 

treatment of the unit involves the risk of severe damages of people 
andmaterial. Details to this refrigerant are found in chapter "refrigerant".

Summary of Contents for HTWS026IX80SR32-I

Page 1: ...TALLATION MANUAL INDOOR UNIT SPLIT ENGLSIH IX80S R32 HTWS026IX80SR32 I HTWS035IX80SR32 I HTWS052IX80SR32 I HTWS071IX80SR32 I Thanks for choosing our product Please read carefully this manual before us...

Page 2: ...U To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device...

Page 3: ...frigerant with no harm to the ozonosphere The influence upon the greenhouse effect is also lower R32 has got very good thermodynamic features which lead to a really high energy efficiency The units th...

Page 4: ...ply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not wash the air conditioner with water to avoid electric sho...

Page 5: ...Do not block air outlet or air inlet It may cause malfunction Do not spill water on the remote controller otherwise the remote controller may be broken When below phenomenon occurs please turn off ai...

Page 6: ...f the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The temperature of refrigerant circuit will be high ple...

Page 7: ...ted by a professional If the length of power connection wire is insufficient please contact the supplier for a new one Avoid extending the wire by yourself For the air conditioner with plug the plug s...

Page 8: ...Air inlet Filter Air outlet Indoor unit Remote controller Actual product may be different from above graphics please refer to actual products NOTE Display Temp indicator Temp indicator Wi Fi indicato...

Page 9: ...isconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use volatile liquid to clean the air condition...

Page 10: ...ck whether drainage pipe is damaged Checking after use season 1 Disconnect power supply 2 Clean filter and indoor unit s panel Notice for recovery 1 Most of packing materials are recyclable materials...

Page 11: ...display when operating remote controller Check whether remote controller appears to be damaged If yes replace it Fluorescent lamp in room Take the remote controller close to indoor unit Turn off the...

Page 12: ...ur source Air conditioner operates normally suddenly Whether there s interference such as thunder wireless devices etc Disconnect power put back power and then turn on the unit again Water flowing noi...

Page 13: ...professional person L1 PG motor indoor zero crossing detecting circuit malfunction Turn off restart after a few seconds if the code occurs again after a few minutes please contact the professional per...

Page 14: ...rea is shown on the nameplate or following table 1 4 Leak test is a must after installation Minimum room area m2 Charge amount kg 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 floor location...

Page 15: ...uld be done when it s removed Safety instructions for transportation and storage 1 Please use the flammable gas detector to check before unload and open the container 2 No fire source and smoking 3 Ac...

Page 16: ...There should be noobstruction near air inlet and air outlet 2 Choose a place where the condensation water can be dispersed easily and won t affect other people 3 Choose a place which is convenient to...

Page 17: ...5 Be sure to cut off the power supply before proceeding any work related to electricity and safety 6 Do not connect the power before finishing inatallation 7 If the supply cord is damaged it must be r...

Page 18: ...use pressure rise or compressor rupture resulting in injury 4 During refrigerant recovery make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the conn...

Page 19: ...gas around the unit it may cause explosion and other accidents 7 Do not use extension cords for electrical connections If the electric wire is not long enough please contact a local service center au...

Page 20: ...pipe The position of piping hole should be a little lower than the wall mounted frame shown as below Left Wall 55 70 Right Mark in the middle of it Level meter Rear piping hole Wall Space to the wall...

Page 21: ...g out the pipe from left or right please cut off the corresponding hole on the bottom case Step 5 Connect the pipe of indoor unit 1 Aim the pipe joint at the corresponding bellmouth 2 Pretightening th...

Page 22: ...er connection wire to the wiring terminal according to the color tighten the screw and then fix the power connection wirewith wire clip 4 Put wiring cover back and then tighten the screw 5 Close the p...

Page 23: ...pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the indoor unit is installed f...

Page 24: ...water outlet can t be placed in water in order to drain smoothly Slant the drain hose slightly downwards The drain hose can t be curved raised and fiuctuant etc The drain hose can t raise upwards The...

Page 25: ...supply according to the voltage marked on the nameplate It may cause malfunction or damaging the parts Is electric wiring and pipeline installed correctly It may cause malfunction or damaging the part...

Page 26: ...rating when first power on and turn on units to ensure the correct installation The steps of test operation is as below A Use remote controller to select cooling mode and set the temperature in 16 C A...

Page 27: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info htwspain com www htwspain com...