GSC53N - GSC57 - ZG47
EN - 73
8. ANALYSER
This function allows the following operations:
display in real time
the electrical parameters of a single phase and three-phase
systems (with and without neutral wire) and the harmonic analysis of voltages and
currents.
conduct a direct Energy measurement
(without memorizing).
memorize
(pressing
SAVE
key) the sampled values of the Parameters present at
instrument input generating a "Smp" record inside instrument memory.
It will be
possible to analyse the memorized
data ONLY by transferring it to a PC.
record simultaneously
(pressing the
START
key after a proper setting): RMS values
of voltages, currents, corresponding harmonics, active, reactive and apparent powers,
power factors and cos , active, reactive and apparent energies, voltage anomalies
(voltage sag and surge) with 10ms resolution.
It will be possible to analyse the
recorded data ONLY by transferring them to a PC.
record simultaneously
(pressing the
START
key) values of Voltage and Current
values coming from test leads and Clamps, using “
Typical Configurations
” with pre-
programmed parameters inside meter (see paragraph 10.2).
It will be possible to
analyse the recorded data ONLY by transferring them to a PC.
It's fundamental the Instrument settings correspond to the Installation type under test and
accessories is use. For this we recommend you to check instrument's setting before
execute an ANALYSIS measurement.
Select the
ANALYSER
rotary switch position. By pressing the
MENU
key the following
screen will be displayed:
MENU GENERAL
SAFETY TEST MEMORY
ANALYSER MEMORY
RESET
ANALYSER CONFIG
RECORDER CONFIG
CONTRAST
DATE&TIME
LANGUAGE
It’s not possible to enter the
MENU
during a recording or a Real Time Energy
measurement.
Generally to check instrument's settings you must check "ANALYSER CONFIG" and
"RECORDER CONFIG" items.