When not in use,
store the equipment somewhere
clean, dry and safe
from thieves and unauthorised users.
Switch OFF the power supply and unplug the unit.
Disconnect all leads and coil them up neatly ready
for return
to your local HSS Hire Weld Depot.
Code 55021
Manual
Electrofusion
Pipe Welder
A manually set welding unit for fusing
pipes up to 400mm in diameter
Operating & Safety Guide HW888
HW888/01
©HSS Hire Service Group Plc 2003 No. HW888/01
Group Office: 25 Willow Lane, Mitcham, Surrey CR4 4TS
Web Site: http://www.hss.com/hireweld
...any comments?
If you have any suggestions to enable us to improve
the information within this guide please fax your
comments or write to the Product Manager at the
address below
Fax: 020 8687 5001
FINISHING OFF
The green button to the right of the unit is the START
button.
Press this to begin the electro-fusion process and
timer.
The arrow
(up and down)
buttons
are used to
alter the
welding time
displayed on the LCD display.
The LCD display will show various information
including the time selected and when welding, the time as
it counts down.
Plug the unit into its power supply and switch the
supply ON.
The LCD will prompt the user to
connect the output
leads to the fitting.
Connect the leads
ensuring a firm
positive connection is achieved.
The unit will then ask for the electrofusion time
for
the particular joint. The time information will be
found on
the joint,
enter the value using the arrow buttons.
Finally,
press the green START button to activate the
weld,
the LCD will display elapsed time.
Once
the weld is
complete, allow the joint time to
cool correctly,
based upon the information from the joint
manufacturer
before disconnecting the output leads
and proceeding to the next joint.
Never push the equipment beyond its design limits.
If it will not do what you want with reasonable ease and
speed, assume you have the wrong type or size of welder
for the job.
Ask at your local HSS Hire Weld Depot for
advice.
Keep the equipment clean.
You will find this less of a
chore if you clean it up regularly rather than wait until the
end of the hire period.
BASIC TECHNIQUES
Fitting
Connection
Socket
Output
Leads
Pipe
Fitting
Joint Information Box
EQUIPMENT CARE