anti-clockwise and lowering to correct height, ttiig
gh
htte
en
n tth
he
e
llo
oc
ck
k b
ba
arr w
wh
he
en
n a
ad
djju
usstte
ed
d..
With all adjustable and jack legs positioned, w
wo
orrk
k a
arro
ou
un
nd
d
tth
he
e u
un
niitt a
ad
djju
ussttiin
ng
g iiff n
ne
ec
ce
essssa
arry
y to bring the unit level,
there are two level bubbles on the top of the lighting
tower. The equipment should be sse
ett sso
o tth
ha
att tth
he
e u
un
niitt
c
ca
an
nn
no
ott b
be
e rro
oc
ck
ke
ed
d..
N
Ne
ex
xtt sse
ett tth
he
e d
diirre
ec
cttiio
on
n o
off tth
he
e m
ma
asstt b
by
y rra
aiissiin
ng
g tth
he
e c
co
on
nttrro
oll
llo
oc
ck
k p
piin
n tth
he
en
n ttu
urrn
n tth
he
e m
ma
asstt tto
o tth
he
e d
de
essiirre
ed
d d
diirre
ec
cttiio
on
n w
wiitth
h
tth
he
e m
ma
asstt h
ha
an
nd
dlle
ess u
un
nttiill tth
he
e llo
oc
ck
k p
piin
n c
clliic
ck
kss iin
ntto
o p
po
ossiittiio
on
n..
You should now start the engine and a
allllo
ow
w iitt tto
o w
wa
arrm
m u
up
p
so that you can raise the mast.
S
Se
ett a
allll ssw
wiittc
ch
he
ess a
an
nd
d c
ciirrc
cu
uiitt b
brre
ea
ak
ke
errss tto
o O
OF
FF
F..
To start the engine ttu
urrn
n tth
he
e k
ke
ey
y tto
o ‘‘G
GL
L’’ ((g
gllo
ow
w)) for a few
seconds until the glow indicator light goes out then ttu
urrn
n
tto
o ‘‘S
ST
T’’ ((S
Stta
arrtt))
If the engine fails to start, e
en
nssu
urre
e tth
ha
att tth
he
e e
em
me
errg
ge
en
nc
cy
y sstto
op
p
b
bu
utttto
on
n iiss rre
elle
ea
asse
ed
d..
You can now raise the mast, e
en
nssu
urre
e tth
he
erre
e a
arre
e n
no
o
o
ov
ve
errh
he
ea
ad
d o
ob
bssttrru
uc
cttiio
on
nss w
wh
hiic
ch
h c
co
ou
ulld
d c
co
om
me
e iin
n c
co
on
ntta
ac
ctt w
wiitth
h
tth
he
e m
ma
asstt..
To elevate the mast simply p
pu
ussh
h tth
he
e m
ma
asstt c
co
on
nttrro
oll iin
n tth
he
e
‘‘u
up
p’’ direction and the mast will elevate to the desired
height.
To lower the mast p
pu
ussh
h tth
he
e c
co
on
nttrro
oll iin
n tth
he
e ‘‘d
do
ow
wn
n’’
direction, ensure the mast is fully lowered.
IIff tth
he
e m
ma
asstt w
wiillll n
no
ott llo
ow
we
err e
en
nssu
urre
e tth
he
e e
em
me
errg
ge
en
nc
cy
y sstto
op
p h
ha
ass
N
NO
OT
T b
be
ee
en
n p
pu
ussh
he
ed
d iin
n..
To turn the lighting tower off, ttu
urrn
n tth
he
e k
ke
ey
y tto
o tth
he
e ‘‘O
OF
FF
F’’
p
po
ossiittiio
on
n..
IIff tth
he
erre
e a
arre
e a
an
ny
y p
prro
ob
blle
em
mss c
co
on
ntta
ac
ctt y
yo
ou
urr llo
oc
ca
all H
HS
SS
S H
Hiirre
e ffo
orr
a
ad
dv
viic
ce
e..
IIff n
no
ott a
allrre
ea
ad
dy
y rru
un
nn
niin
ng
g,, sstta
arrtt tth
he
e g
ge
en
ne
erra
atto
orr as described in
‘GETTING STARTED’.
O
On
nc
ce
e rre
ea
ad
dy
y sse
ett tth
he
e ffo
ou
urr lla
am
mp
p M
MC
CB
B’’ss ((m
ma
arrk
ke
ed
d L
LA
AM
MP
P1
1
L
LA
AM
MP
P2
2 L
LA
AM
MP
P3
3 L
LA
AM
MP
P4
4)) o
on
ne
e a
att a
a ttiim
me
e tto
o O
ON
N,, A
AL
LL
LO
OW
W
E
EA
AC
CH
H L
LA
AM
MP
P T
TO
O F
FU
UL
LL
LY
Y IIL
LL
LU
UM
MIIN
NA
AT
TE
E ((2
2 m
miin
nss)) B
BE
EF
FO
OR
RE
E
T
TU
UR
RN
NIIN
NG
G T
TH
HE
E N
NE
EX
XT
T L
LA
AM
MP
P O
ON
N.. IItt iiss v
ve
erry
y iim
mp
po
orrtta
an
ntt tto
o
o
on
nlly
y ssw
wiittc
ch
h tth
he
em
m o
on
n o
on
ne
e a
att a
a ttiim
me
e..
To turn off the lights return the MCB’s to OFF.
T
To
o sstto
op
p tth
he
e lliig
gh
httiin
ng
g tto
ow
we
err ttu
urrn
n tth
he
e k
ke
ey
y tto
o tth
he
e O
OF
FF
F
p
po
ossiittiio
on
n..
4 Head Metal
Halide Lighting
Tower
4 Head Metal
Halide Lighting
Tower
Operating & Safety Guide 492
Operating & Safety Guide 492
A towable lighting tower with
four 1000W metal halide
lighting heads
Code 57137
492/01
492/01
©HSS Hire Service Group Ltd 2008 No. 492/01
Group Office: 25 Willow Lane, Mitcham, Surrey CR4 4TS
Web Site: http://www.hss.com
…any comments?
If you have any suggestions to enable us to improve
the information within this guide please e-mail your
comments or write to the Safety Guide Manager
at the address below
e-mail: [email protected]
R
Re
eg
gu
ulla
arrlly
y c
ch
he
ec
ck
k tth
he
e ffu
ue
ell lle
ev
ve
ell a
an
nd
d tto
op
p u
up
p a
ass n
ne
ec
ce
essssa
arry
y
w
wiitth
h c
clle
ea
an
n ffrre
essh
h d
diie
esse
ell..
N
No
otte
e:: T
Th
hiiss u
un
niitt iiss ffu
ulllly
y b
bu
un
nd
de
ed
d a
an
nd
d ssh
ho
ou
ulld
d b
be
e c
ch
he
ec
ck
ke
ed
d
d
da
aiilly
y a
an
nd
d d
drra
aiin
ne
ed
d iiff n
ne
ec
ce
essssa
arry
y..
R
Re
eg
gu
ulla
arrlly
y c
ch
he
ec
ck
k tth
he
e o
oiill lle
ev
ve
ell - when the engine is cold
and on level ground. Withdraw the dipstick, wipe it
clean, then replace it, remove it a second time and verify
that the oil level is between the min and max lines, top
up as necessary.
C
Ch
he
ec
ck
k h
hy
yd
drra
au
ulliic
c o
oiill by unscrewing the oil cap which is
located on the main panel (this must be done when the
m
ma
asstt iiss d
do
ow
wn
n), check the dipstick as with the engine oil.
If the engine stops, c
ch
he
ec
ck
k tto
o sse
ee
e iiff tth
he
e o
oiill p
prre
essssu
urre
e lla
am
mp
p
o
on
n tth
he
e m
ma
aiin
n p
pa
an
ne
ell iiss n
no
ott iillllu
um
miin
na
atte
ed
d,, top up as necessary.
When not in use, store the equipment somewhere clean,
dry and safe from thieves.
EQUIPMENT CARE
S
Stto
op
p tth
he
e lliig
gh
httiin
ng
g tto
ow
we
err b
by
y ttu
urrn
niin
ng
g tth
he
e k
ke
ey
y tto
o tth
he
e ‘‘O
OF
FF
F’’
p
po
ossiittiio
on
n a
an
nd
d w
wa
aiitt u
un
nttiill tth
he
e e
en
ng
giin
ne
e sstto
op
pss..
If you have finished with the equipment completely, you
should n
no
ow
w c
clle
ea
an
n u
up
p tth
he
e u
un
niitt..
If the unit has been used to power auxiliary power,
d
diissc
co
on
nn
ne
ec
ctt a
allll c
ca
ab
blle
ess b
be
effo
orre
e llo
ow
we
erriin
ng
g tth
he
e m
ma
asstt..
When ready llo
ow
we
err tth
he
e m
ma
asstt b
by
y rre
ev
ve
errssiin
ng
g tth
he
e iin
nssttrru
uc
cttiio
on
nss
tto
o rra
aiisse
e iitt iin
n ‘‘G
GE
ET
TT
TIIN
NG
G S
ST
TA
AR
RT
TE
ED
D’’
C
Ch
he
ec
ck
k a
allll llo
oc
ck
k p
piin
nss,, c
clla
am
mp
pss,, sstta
ab
biilliisse
errss a
an
nd
d lle
eg
gss a
arre
e
c
co
orrrre
ec
cttlly
y sstto
ow
we
ed
d a
an
nd
d sse
ec
cu
urre
e ready for return to your
local HSS Hire.
BASIC TECHNIQUES
FINISHING OFF
LAMP 2
LAMP 3
LAMP 1
LAMP 4
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Glow
indicator
Key start
M
Ma
aiin
n P
Pa
an
ne
ell
Mast control
Hydraulic
Oil
... have you been trained
The law requires that personnel using work equipment have
received adequate training and must be competent when
using the equipment within the workplace.
Training is available at HSS Training Solutions
0
08
84
45
5 7
76
66
6 7
77
79
99
9