www.hscuk.co.uk
SPK450/SPK450M/SPK450AF series
Pump Operation Manual
Page 1: ...www hscuk co uk SPK450 SPK450M SPK450AF series Pump Operation Manual ...
Page 2: ... the manufacturer it s service agent or similarly qualified persons in order to avoid a hazard 8 Pollution of the liquid could occur due to leakage of lubricants from pump 9 The pump is electrically connected Ensure that it is isolated from electrical supply during installation and any subsequent service work 10 This appliance is not intended for use by persons including children with reduced phys...
Page 3: ...ONS Type of liquid clean water with no suspended abrasive material PH value 6 5 8 5 Max liquid temperature 40 Max Submersion Depth 5m Max Diameter of solids 2 0mm Protection Class IP68 Insulation Class B TECHNICAL DATA Pump Model Power W Outlet Diameter Voltage V HZ Max Flow l min Max Head G W kg Carton Size mm SPK450 450W 1 110 50 85 10 11 5 23 23 35 SPK450M 450W 2 110 50 260 11 10 0 23 23 35 SPK...
Page 4: ...e with these instructions 2 Check pump technical data For electrical and model details please double check the rating plate to ensure the pump is suitable 3 Locating the Pump Do not use the electrical cable to lift or transport the pump You must use the handle on top of the pump to lift the pump Using the handle at the top of the pump connect a nylon rope or a stainless steel cable suitable to sus...
Page 5: ...upported independently of the pump 7 Float Switch SPK450AF is with float switch SPK450 SPK450M is without float switch The function of float switch is to control pump working automatically The pump works when the float is higher than certain level and stops operating when pump float is in the low position Please check that the float switch is free from any obstacle before using the pump 8 Filter M...
Page 6: ...tore in a dry place The pump should be checked for any damage to the unit and power cable and repaired straight away with genuine spare parts This should be done by a suitably qualified person only TROUBLE SHOOTING GUIDE Symptom Cause Remedy Pump does not start Float switch isn t in the on position SPK450AF Only Wait until there is enough water in the pit to start the pump Float is caught on somet...
Page 7: ...its are observed Pump runs intermittently When the pump shuts off water in the discharge line is running back into the pit lifting the float switch SPK450AF Only Fit a non return valve at the pump discharge so that water cannot return to the pit SERVICE Pump should only be serviced by qualified personnel For best results use only genuine service parts To avoid dangerous or fatal electrical shock h...
Page 8: ...complete lack of maintenance Chemical electrochemical or electrical influences Thank you for choosing Elite pumps The Hire Supply Company UK Limited Sheet Stores Industrial Estate Long Eaton Nottingham NG10 1AU UK Tel 0845 309 0707 ...