Introduction
This floodlight incorporates an automatic PIR sensor with two PAR38
lamps. The sensor continuously scans a preset operating zone and
immediately switches the floodlight on when it detects movement
from people and animals. It can be used to illuminate pathways, steps,
patios, porches or other areas that require lighting for reasons of safety,
convenience or security. Whilst there is movement within the scanning
area the floodlight will remain on.
Where to fit your floodlight
Before selecting a place to install your floodlight you should note that
movement across the scan area is more effective than movement directly
toward or away from the sensor (refer FIG. 1B). If movement is made
walking directly towards or away from the sensor and not across, the
apparent detection range will be substantially reduced (refer FIG. 1A).
Always mount the MPES181BP sensor light in a sheltered position, i.e.
under the eaves of the house.
Ideally the floodlight should be mounted 1.8-2.5m above the area to be
scanned (refer to Fig. 3).
Installation
For installation of the floodlight, please refer to Fig. 2.
1. This product must be installed by a licensed electrician according to
AS/NZS 3000.
2. Switch power off at the meter box to isolate circuit.
3. Unscrew the Fixing Cover Screws then remove the cover and
Cable Gasket.
4. Remove the Cable Anchorage and Terminal Block.
5. Use the plastic back plate to mark the position of screw holes onto
mounting surface. Drill the wall to depth of about 4cm and fit the
wall plugs (supplied). Be aware of drilling or screwing into concealed
electrical wiring.
6. Ensure the cable passes through the Cable Gasket and connect cable
to Terminal Block.
7. Affix the back plate to the mounting surface with Mounting Wall
Screws (supplied).
8. Re-fit the Terminal Block and Cable Anchorage.
9. Re-fit the cover.
10. Insert the PAR38 lamps (supplied). Please ensure the sealing rubber
(supplied), is placed on the lamp holder prior to installation of
PAR38 lamps.
Important: loosen all lock nuts and screws on sensor and lamp holders
before making any adjustments.
DO NOT MEGGER TEST.
Instruction Manual
Twin Floodlight with Sensor
Cat. No. MPES181BP
Fig. 1B
Highest Sensitivity
Fig. 1A
Lowest Sensitivity
2.5 Metres
4M
8M
approx.120
0
12M
Fig. 3
Fig. 4
1 Terminal Block
2 Cable Anchorage
3 Cable Gasket
4 Power Cable
5 Fixing Cover Screw x 2
6 Gasket Piece
7 Mounting Wall Screw x 2
Fig. 2