background image

Excel and Linea  

Dual USB Charger Mechanism

Cat no. 770USB2PSAMWE 

770USB2PSAMBL 

770USB2PSXMWE 

770USB2PSXMBL 

Instruction Sheet

Installation in powerpoints

Installation in switch plates

2.  Join wires with corresponding Mains cables in the ‘A’ 

and ‘N’ terminals of powerpoint.

2b.  Configuration with USB mechanism installed 

next to a switch on a plate. Connect USB 

wires to switch mechanism as per below.

1. Push USB mechanism into extra function hole with arrows facing up as shown.

1.  Push USB mechanism into extra function 

hole with arrows facing up as shown.

2a.  Configuration with USB mechanism stand alone in plate. 

Connect USB module wires to the mains cable via insulated 

connectors (401 series) as per diagram below.

1

2

  Features 

  Installation 

Cat No. 

 770USB2PSAMWE, 770USB2PSAMBL, 770USB2PSXMWE, 770USB2PSXMBL 

Ouput: 

 5V d.c. ± 5%  4.8 A 

Input current 10A (GPO): 

 230-240V a.c.  50Hz 

Mains connections: 

 Via ‘A’ and ‘N’ wires 

Standby power consumption: 

 ‹ 0.07W 

Overload protection on output: 

5.1A

NOTE:  USB charger mechanism can be assembled with Excel and Linea powerpoints and switch plates (if Neutral is available) and 

powerpoints with extra function hole. 

Mains cable

Insulated 

connetors 

401

WIRING OF USB DRIVER

TO MAINS WIRING WITH 401 

CONNECTOR (REQ. NEUTRAL)

ACTIVE - OUT

(TO LIGHT)

MAINS

ACTIVE

IN

NEUTRAL

IN

USB

USB

MAINS

770USB2PSAMWE 

770USB2PSAMBL

770USB2PSXMWE 

770USB2PSXMBL

Summary of Contents for 770USB2PSAMWE

Page 1: ...ith USB mechanism stand alone in plate Connect USB module wires to the mains cable via insulated connectors 401 series as per diagram below 1 2 Features Installation Cat No 770USB2PSAMWE 770USB2PSAMBL 770USB2PSXMWE 770USB2PSXMBL Ouput 5V d c 5 4 8 A Input current 10A GPO 230 240V a c 50Hz Mains connections Via A and N wires Standby power consumption 0 07W Overload protection on output 5 1A NOTE US...

Page 2: ...k wall Wall cavity Plasterboard 0 8Nm 1 Push assembled unit into the wall cavity 2 Screw the unit to wall with standard mounting accessories and then fix front plate Plasterboard Mains cable Wall cavity Cable tie box to Mains cable to avoid strain on USB mechanism Metal bracket Brick wall 0 8 Nm Brick wall Plasterboard Mains cable Wall cavity Cable tie box to Mains cable to avoid strain on USB mec...

Page 3: ...h corresponding mains cables Use junction box 404 or equivalent for mains wiring connection USB driver Connect mains cables to GPO Ceiling Insulation area CLICK Note In application requiring the 3m USB extension lead it shall not share the same conduit as the 240V a c mains wiring in accordance with the Wiring Rules The 3m extension lead is suitable for a standard Ø20mm conduit Do not cover this U...

Page 4: ...stant vibration temperature fluctuations or areas of high humidity This product contains no serviceable parts and no attempt should be made to repair this product If the product is faulty it should be discarded This product has been designed to operate in ambient temperatures 5 C to 40 C The material in this product may vary in colour from batch to batch Colour matching from one batch to another c...

Reviews: