HPF H7-90-AT Manual Download Page 16

Page 

16

 of 

17

 

 

Warranty   

 

 

 

 

 

 

 

    

 

I. General Warranty 

Water Filter Systems¹ (Excluding consumables) Manufactured or Assembled² by High Performance Filtration (HPF) 

are covered under a 12-month Warranty Against Defects (Manufacturer’s Warranty). This warrants the water filter 

system to be free from defects in material and workmanship for a period of 12 months from date of sale. 

If applicable, HPF may cover the return freight in the form of a re-imbursement after the system has been inspected 

and confirmed it is a valid warranty claim. 
HPF will not cover any labour charge incurred by the consumer for the replacement or repair of a product. The 

warranty is strictly parts only for the parts supplied by HPF. This warranty only applies to the original consumer of the 

product and is non-transferable. If you have purchased the system through a re-seller, please contact them to 

facilitate the warranty on your behalf. All replaced or exchanged parts become the property of HPF. 

HPF does not cover the workmanship of the plumber who originally installed the system. Responsibility for damages 
that occur during installation fall with the plumber. 

 

II. Qualification for Warranty 

As per Australian Plumbing Codes, all filter systems must be installed by a qualified plumber. The consumer is 

responsible for keeping record and proof of installation in the form of an invoice and/or receipt. 

Filter systems must be maintained as per HPF recommendations³ including the use of replacement filters, fittings and 

components supplied by HPF. Failure to maintain the filtration systems using HPF supplied/approved products may 

void warranty. 

The warranty only applies if the product was used and/or installed in accordance with the user guide and/or 

installation instructions. This warranty is given in lieu of all other express or implied warranties and manufacturer 

shall in no circumstance be held liable for damages consequential or otherwise or delays caused or faulty 
manufacturing except as excluded by law. 

Warranties need to be approved by HPF to ensure the product was not incorrectly used, installed, or claimed. False 

and incorrect claims will be pursued at HPF’s discretion including chargeable inspection and transit costs incurred.  

HPF does not take responsibility for retaining customer records, it is the consumer’s responsibility to retain all 

invoices or proof of purchase from the original sale and ongoing maintenance records as proof of upkeep. 
 

III. Exclusions 

HPF Standard Warranty shall be void if the product sustains damage or failure resulting from any of the following: 

 

If the system was not installed in accordance with the manufacturers instruction manual. 

 

If your system(s) fails to be maintained in accordance with recommended servicing and as per the 

manufacturers operating instructions. 

 

Cross threading or damage to screws and/or threads 

 

Unauthorised or abnormal use or operation. 

 

Exposure to unsuitable environmental conditions*. 

 

Warranty – Australia 

This warranty is given by High Performance Filtration (Jacknel Pty Ltd ATF The J & N Family Trust). ABN 64 855 305 

562 Located at 7/38 Jade Drive, Molendinar QLD 4214. Ph 07 5597 6142 & email [email protected] 

This warranty is provided in addition to other rights and remedies you have under law. Our products come with 

guarantees which cannot be excluded under the Consumer Guarantees Act. 
 

IV. Extended Warranty 

The H7-90 UV system is eligible for a conditional extended 4-year warranty (commencing no later than 12 months 
from the sale date), to provide a total warranty period of 5 years. This extended warranty is subject to terms and 

conditions outlined below. This extended warranty covers the below parts of the system. 

 

Ultraviolet Chamber 

 

 

rev 1.0 | 30/09/2021

 

Summary of Contents for H7-90-AT

Page 1: ...d How Does It Work 4 IX Installation with other Systems 5 Installation Introduction 5 I Site Preparation 5 II System Installation 6 III Mounting 6 IV Installing Connections 6 V Filter Protection 6 Ultraviolet System Installation 7 I Thimble Quartz Tube Installation 7 II UV Lamp Installation 9 III Ballast Operation 10 Maintenance 12 I General Maintenance 12 II Lamp Replacement 12 III Thimble Quartz...

Page 2: ...must be carried out by a qualified plumber or authorised technician The power supply should always be plugged directly into a surge protector Standard power supplies are NOT water proof and must be installed out of the elements to avoid water damage This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and kn...

Page 3: ...ain power off unplug the electrical connection and then retrieve the unit if safe to do so Do not operate this unit if it has a damaged cord or plug if it is malfunctioning or if it has been dropped or been damaged in any manner Always disconnect the water supply and completely drain the water purifier if it will be subjected to temperatures below freezing for extended periods of time Overheating ...

Page 4: ...riefly shut down for routine cleaning or during power interruptions where water could have passed through the system the aforementioned pipe disinfection procedure must be conducted again The UV system should be installed after a filter on the return line This helps ensure that the water is clear of debris and impurities that could inhibit the disinfection process and increase the risk of damage t...

Page 5: ...re usually installed on Rainwater Systems to counteract the pH of acidic rainwater which usually causes green blue staining in the water or on fixtures The calcite filter is usually installed as stage 1 as it is a back washable media vessel followed by the Big Blue System Water Softener Water softeners are common on both mains water and also bore water installations For bore water installations it...

Page 6: ...access for maintenance Also allow at least 500mm height clearance for the UV lamp installation maintenance The mounting location will require a 10A GPO within 1 5m from the left side of the system for the UV power supply If mounting on an uneven surface such as rough brick it is recommended to install a spacer behind the mounting holes so the unit is sitting slightly off the wall to allow easier a...

Page 7: ...rt the glass thimble into the chamber from the top see picture right DO NOT DROP THE THIMBLE INSIDE THE CHAMBER AS IT WILL SHATTER 3 Allow equal parts of the thimble to be exposed from each end of the chamber and slide the O Rings over each end of the glass shown below Be careful not to drop the glass at this point Once the O rings are seated this will assist in holding the glass in place It is re...

Page 8: ...tening the nuts because it is likely that the bottom nut has caused the thimble to shift off centre You will need to loosen off the bottom nut and push the glass back down before continuing with tightening If you experience issues with this please contact the distributor or manufacturer for assistance 7 When following the next commissioning steps take the time to check the chamber for leaks once i...

Page 9: ... of the pins so they will only go into the power supply one way Ensure the connection is firm and plugged in all the way 4 Lower the lamp carefully down into the thimble until the lamp makes contact with the spring as shown to the right Then gently slide wiggle the white cap over the knurled nut 5 Connect the Green Yellow earth wire to the small nut per the below and finger tighten the nut over it...

Page 10: ...tomof ballast power source as shown picture to the right The earth wire must be affixed securely WORKING CONDITIONS The Lamp and Ballast are working correctly when the Green LED Indicator Light shows Display Screen Press the SELECT button for 2 seconds to toggle between the Lamp Life Remaining Days Default Display Screen and the Total Running Days Ballast Operation Time Lamp Life Remaining Days De...

Page 11: ...the button and the timer is successfully reset ERROR FAULT CONDITIONS Whilst it is usually the lamp that requires replacement please refer to the below guidance along with the Troubleshooting section of this guide to diagnose which element requires replacement LAMP FAILURE The Lamp has failed when the Red LED Indicator Light shows and or the system is alarming Note The Lamp Life will display 0 but...

Page 12: ... Steps 2 to step 6 to reinstall new lamp 8 Reset the Ballast Timer per Ballast Operation Instructions Lamp Replacement Due III Thimble Quartz Tube Replacement 1 Turn off power 2 Shut off water supply to UV system via inlet and outlet valves 3 Drain the chamber 4 Follow lamp replacement steps above to remove UV lamp 5 Twist off nuts from reactor chamber 6 Remove O ring 7 Remove quartz sleeve and wi...

Page 13: ...s a crack or hole in the thimble it will fill from the inside out Turn off the water carefully remove the thimble and replace with a new one If the thimble releases and shards of glass this chamber and downstream plumbing will need to be thoroughly checked and any glass removed before re connection High Water Temperature 1 Low Flow Rate 2 Oversized System 1 If there are periods of low water usage ...

Page 14: ...mp is still working turn the power off for five minutes check connections and then turn it back on to see if the fault clears No Lights on Ballast 1 Ballast failure 2 interrupted power supply 1 in the event of a large surge it is possible that the ballast failed This can also occur from shorts and water ingress cheque for signs of a short around the lamp connexion end The ballast will need to be r...

Page 15: ...ely 4 Have source water test for turbidity use cartridges with higher filtration precision Water appears milky 1 Caused by air in the water lines 1 Run water till air is purged Moisture inside the Quartz Sleeve 1 Quartz Sleeve is broken cracked or O ring not properly sealed 1 Visually inspect the Quartz Sleeve If broken or cracked replace thimble Re install the Thimble if the O rings are not prope...

Page 16: ...ranty is given in lieu of all other express or implied warranties and manufacturer shall in no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law Warranties need to be approved by HPF to ensure the product was not incorrectly used installed or claimed False and incorrect claims will be pursued at HPF s discretion in...

Page 17: ...ty claimafter 6 months from date of original invoice the discount will be 50 from the next purchase of a replacement UV lamp Pro Rata Warranty only applies for a single use within the pro rata period 12 months Pro Rata Warranty only applies to components purchased new at full list price or as part of an applicable UV system Due to a large range of factors cartridges for the filter system are not c...

Reviews: