Abstract

This document describes how to install, configure, and maintain HPE StoreVirtual 3000 File
Controller and is intended for system administrators. For the latest version of this guide, go to
https://www.hpe.com/support/manuals.

Summary of Contents for StoreVirtual 3000

Page 1: ...8S69 96121A Published March 2017 Edition 1 Abstract This document describes how to install configure and maintain HPE StoreVirtual 3000 File Controller and is intended for system administrators For th...

Page 2: ...ard Enterprise required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are lic...

Page 3: ...Initial Configuration Tasks 17 Standalone or Single Node Configuration 18 System Settings 18 Networking 18 Storage Management 19 Notifications 21 Storage Configuration 21 Configure Cluster 23 Protect...

Page 4: ...e 68 Online spares 68 Logical storage elements 68 Logical drives LUNs 68 Partitions 69 Volumes 69 File system elements 70 File sharing elements 70 Volume Shadow Copy Service overview 70 Using storage...

Page 5: ...management 87 Folder management 87 Share management 93 Share considerations 94 Defining Access Control Lists 94 Integrating local file system security into Windows domain environments 94 Comparing adm...

Page 6: ...cific issues 108 Non cluster aware file sharing protocols 109 Adding new storage to a cluster 109 Creating physical disk resources 109 Creating file share resources 109 Creating NFS share resources 11...

Page 7: ...ith a DVD or USB flash device 135 Recovering both servers 135 Recovering a single server 136 Backing up and restoring HPE StoreVirtual 3000 File Controller with Windows Recovery Environment 137 Produc...

Page 8: ...are to significantly reduce the time and complexity of installation For more information about HPE StoreVirtual 3000 File Controller features go to https www hpe com us en storage storevirtual html Ha...

Page 9: ...ork Configuration Tasks window which are used to set up and manage HPE StoreVirtual 3000 File Controller The Windows Server Manager Tools StoreVirtual menu provides a collection of HPE and Microsoft u...

Page 10: ...rage Server 2016 Standard Edition operating system with Microsoft iSCSI Software Target and a Microsoft Cluster Service MSCS license included Default roles This section includes the list of roles that...

Page 11: ...Work Folders Storage Services Print and Document Services Print Server Internet Printing Line Printer Daemon LPD Service Web Server IIS Web Server Common HTTP Features Default Document Directory Brow...

Page 12: ...r of HPE StoreVirtual 3000 File Controller Certificate of Authenticity COA and End User License Agreement EULA Record the serial number and COA product key and make a print copy of the EULA as needed...

Page 13: ...ts standalone system depending on your configuration to verify network connectivity Consult with your network administrator to confirm test results Table 2 Validation tests clustered system Test Comma...

Page 14: ...he HPE StoreVirtual 3000 File Controller system from another system on the same network ping system address Ping the IP address of some other system on the same network form the HPE StoreVirtual 3000...

Page 15: ...Host Configuration Protocol server Connect the following cables to the back panel of HPE StoreVirtual 3000 File Controller in this sequence keyboard mouse network cables monitor cable and power cable...

Page 16: ...ller system starts and displays the Setup Windows wizard in which you select language and regional settings and accept the license agreement 2 After completing the wizard you are asked if you want to...

Page 17: ...and selected the standalone configuration when you first powered on the server you can continue to follow the installation steps for the single node cluster To join a node to an existing cluster foll...

Page 18: ...he default password is the password that you entered during the initial setup of the server To change the password enter the new password in the New password and Confirm password fields and click OK I...

Page 19: ...centralized database that is replicated among the domain controllers To name the computer and join it to a domain clickProvide computer name and domain in the Initial Configuration Tasks window and t...

Page 20: ...hed at the time of implementation The IP address is the Virtual IP address established on the StoreVirtual Storage Array For additional information about the StoreVirtual Array Management refer to the...

Page 21: ...ve proactive notifications of system updates critical issues and announcements of feature updates If your system is connected to a network that can access the Internet you can perform the product regi...

Page 22: ...rop down menu 5 Select Read Write in the Permissions drop down menu assigned to this export 6 Click Export to export virtual disk to a StoreVirtual File Controller server or cluster The volume is now...

Page 23: ...e share name Click Next 7 The Shared Folder Permissions screen is displayed Click All users have a read only access radio button 8 Click Finish The Sharing Successful screen is displayed The status me...

Page 24: ...a cluster in the Configure Cluster task group in ICT The Cluster Configuration tool is launched 2 Enter the cluster name in Provide Cluster Name 3 Click Validate cluster to validate the node 4 Click J...

Page 25: ...eps can vary These additional steps can include Running Microsoft Windows Update HPE highly recommends that you run Microsoft Windows updates to identify review and install the latest applicable criti...

Page 26: ...rtual 3000 File Controller powers up and if you are creating a two node cluster the first node discovers the second node by default This default connection occurs only if a physical connection exists...

Page 27: ...will be a member of the cluster Networking Clicking this link launches the Network Configuration Tool wizard that enables you to configure network interfaces network teams VLANs and network interface...

Page 28: ...he interface is excluded from all configurations and is not modified 2 Enter the new interface name The new name that you enter must not contain special characters such as and 3 Click Next to proceed...

Page 29: ...interface name If all adapters are already claimed by one or more teams a warning message is displayed You can either go back and remove some interfaces from the previously created teams or skip the c...

Page 30: ...sing the interface pane Each interface that can be configured is enabled on the system even if no changes are made to the interface The IP addresses that you assign can be static or dynamically assign...

Page 31: ...configuration is successful but the creation of teams or VLANs fails then the NCTConfig xml file is created with only the physical network interfaces listed in the file The VLANs and teams are not li...

Page 32: ...e instance After successfully importing the settings when you launch NCT a confirmation message is displayed indicating if you want to use the last used network configuration settings If you click Yes...

Page 33: ...logic to assign LUNs The smallest LUN that is larger than 500 MB will be used as the quorum disk in the cluster Any additional LUNs will be assigned to the file server that will be created If you wan...

Page 34: ...ual Storage Array setup documentation and export volumes to servers or server clusters Register StoreVirtual Storage Array Registering the StoreVirtual Storage Array enables the StoreVirtual File Cont...

Page 35: ...ches your storage array A DSM is required by your storage vendor When complete a message is displayed indicating that system reboot is needed Do not reboot the system at this point Open the applet at...

Page 36: ...hared storage is not discovered You can perform the following tasks in cluster configuration Provide cluster name and domain Prepare witness disk Create virtual disks for StoreVirtual file controller...

Page 37: ...elect Volumes from the StoreVirtual drop down menu to display the Volumes screen 4 Click Create Volumes and the Create Volume window is displayed 5 Specify the name for a volume Note Name must be uniq...

Page 38: ...specify the volume size 3 Click Next The Assign Drive Letter or Path screen appears 4 Click Assign the following drive letter radio button 5 Click Next The Format Partition screen appears 6 Click Form...

Page 39: ...gory Network Validate IP Configuration Adapters Server Management and 1 GbE Public 1 on node node name have IP addresses on the same subnet This may be intentional since both adapters are currently No...

Page 40: ...or on a server where you installed the Failover Clustering feature start Failover Cluster Manager To do this on a server start Server Manager and then from the Tools menu select Failover Cluster Manag...

Page 41: ...click Finish Then continue to Create the Cluster Failover procedure b If the results indicate that there were warnings or failures click View Report to view the details and determine which issues must...

Page 42: ...at you plan to add as a failover cluster node and then click Add Repeat this step for each server that you want to add To add multiple servers at the same time separate the names by a comma or a semic...

Page 43: ...e computer objects for the cluster nodes reside This can be either the default Computers container or an OU To specify a different location for the CNO you can enter the distinguished name of an OU in...

Page 44: ...through Failover Cluster Manager or Failover Clustering Windows PowerShell cmdlets and have not yet created storage spaces in File and Storage Services Figure 11 Create Cluster Wizard Confirmation Cl...

Page 45: ...nings may also be ignored or the warnings can be avoided altogether by disabling unused network adapters using the Control Panel These warning are due to the Cluster Internal network that is auto conf...

Page 46: ...Server 2016 which is called an Update Coordinator is configured with the CAU tools The Update Coordinator is not a member of the cluster that is updated during the Updating Run From the remote compute...

Page 47: ...ge directly by double clicking the Vision Solution Double Take Availability Information icon on the desktop Configuring failover properties for multi site environments You can configure failover prope...

Page 48: ...Controller in the Computer box and click Connect 3 Log on to the HPE StoreVirtual 3000 File Controller with the administrator user name and password Using the Telnet method Telnet is a utility that en...

Page 49: ...e of the HPE StoreVirtual 3000 File Controller that is used by HPE Support to diagnose any problems Data collection progress is shown and when complete Windows Explorer opens to the folder containing...

Page 50: ...screen Click the Configure Networking icon on the desktop The NCT is divided into two panes When you launch NCT to configure network interfaces or validate the network configuration the network confi...

Page 51: ...PCI adapters into a virtual adapter This virtual adapter is seen by the network and server resident network aware applications as a single network connection For more information on Microsoft s implem...

Page 52: ...sed for new teams NOTE When a team is created a default virtual network interface is also created To remove the default virtual interface assign one or more VLAN IDs on the Network VLAN Configuration...

Page 53: ...ssignments The default VLAN ID is 0 but the VLAN IDs can have a value from 0 to 4094 Each VLAN ID assigned to a physical network interface or network team creates a virtual network interface Both phys...

Page 54: ...links at the bottom of the page to correct the errors To apply the configuration changes click Apply When you apply the changes and click Next the details of each task configured is displayed If some...

Page 55: ...n on importing the network configuration see Importing network configuration Network Interface IP Configuration Network Interface enables you to begin the IP address configuration by selecting the int...

Page 56: ...ask Assigning a default gateway address is optional 2 Select Use DHCP to assign DNS server addresses or Assign a static IP address and gateway If you selected the Assign a static IP address and gatewa...

Page 57: ...to validate the network settings However HPE recommends using the network validation system to confirm that your network settings are valid and to help diagnose environmental network issues You can la...

Page 58: ...dation failed at the first task When the file is created successfully you can use it to import the configuration from one server to another Important considerations while working with the NCTConfig xm...

Page 59: ...UpperRangeLimit UpperRangeLimit LowerRangeLimit LowerRangeLimit VLANType SingleVLAN VLANType VLANIDs VLANID 45 VLANID VLANIDs CanMoveForward true CanMoveForward VLANforTeam TeamMembers TeamMember Eth...

Page 60: ...he setting of the IP configuration fails The StaticEnabled and DHCPEnabled tags cannot be set to true at the same time Importing network configuration The NCTConfig xml file enables you to directly im...

Page 61: ...overy completes 6 Make required network configuration changes on the respective windows 7 Click Apply on the Network Configuration Summary window to apply the changes 8 Click Validate on the Network C...

Page 62: ...d set up one or more servers as a file server by installing the File and Storage Services role and the appropriate role services Administrators can use the File and Storage Services role to setup and...

Page 63: ...in your organization You can use Print Management from any computer running Windows Storage Server 2016 and you can manage all network printers on print servers running Windows Storage Server 2008 Win...

Page 64: ...For more information about NFS see the following Microsoft website The Storage Team at Microsoft File Cabinet Blog 64 Administration tools...

Page 65: ...elements Physical storage elements Logical storage elements File system elements File sharing elements Each of these element is composed of the previous level s elements Storage management example Sto...

Page 66: ...orage management occurs at the physical drive level Choosing the best physical disk configuration requires understanding the following Current corporate and departmental structure Current file server...

Page 67: ...uration may not be possible or necessary Figure 14 Configuring arrays from physical drives Because the read write heads are simultaneously active the same amount of data is written to each drive durin...

Page 68: ...gning an online spare or hot spare to any configuration except RAID 0 This hard drive contains no data and is contained within the same storage subsystem as the other drives in the array When a hard d...

Page 69: ...ts in conjunction with NFS shares is not supported The GUID partition table GPT disk partitioning style supports volumes up to 18 exabytes in size and up to 128 partitions per disk Unlike MBR partitio...

Page 70: ...requirements increased within the allowable growth limits File system elements File system elements are composed of the folders and subfolders that are created under each logical storage element part...

Page 71: ...NFS shares Clustered server elements HPE StoreVirtual 3000 File Controller systems supports clustering These storage systems support several file sharing protocols including DFS NFS FTP HTTP and Micr...

Page 72: ...re running SSA you will be prompted to select the Execution Mode for SSA Selecting Local Application Mode allows you to run the SSA from a Remote Desktop remote console or HPE StoreVirtual 3000 File C...

Page 73: ...RAID configurations Use meaningful volume labels with the intended drive letter embedded in the volume label if possible For example volume e might be named Disk E Volume labels often serve as the onl...

Page 74: ...ed disk space warning level When enabling disk quotas it is possible to set both the disk quota limit and the disk quota warning level The disk quota limit specifies the amount of disk space a user is...

Page 75: ...t of free space in the array changes The expansion process is entirely independent of the operating system NOTE See your storage array hardware user documentation for further details about expanding s...

Page 76: ...he original volume In the snapshot s original form it takes up no space because blocks are not moved until an update to the disk occurs By using shadow copies an HPE StoreVirtual 3000 File Controller...

Page 77: ...disk space When determining the amount of space to allocate for storing shadow copies consider both the number and size of files that are being copied as well as the frequency of changes between copi...

Page 78: ...es to be deleted If the sudden deletion of shadow copies is unacceptable to administrators or end users it is best to use a separate volume on separate disks to store shadow copies Determining creatio...

Page 79: ...ng shadow copies The vssadmin tool provides a command line capability to create list resize and delete volume shadow copies The system administrator can make shadow copies available to end users throu...

Page 80: ...ance Shadow copies on a source volume must be continually monitored and can consume space designated for file sharing Setting the limit too high takes up valuable storage space Setting the limit too l...

Page 81: ...s also possible to create new shadow copies or delete shadow copies from this page Set schedules Shadow copy schedules control how frequently shadow copies of a volume are made There are a number of f...

Page 82: ...at volume if enabled click Disable 6 Click Settings 7 In the Located on this volume field select an available alternate volume from the list NOTE To change the default shadow copy schedule settings cl...

Page 83: ...system versions No additional software is required to enable UNIX users to independently retrieve previous versions of files stored on NFS shares NOTE Shadow Copies for Shared Folders supports retriev...

Page 84: ...shadow copies for shares to which they have access In other words if a user does not have access to a share he also does not have access to the share s shadow copies The Shadow Copies for Shared Folde...

Page 85: ...ow copies all pseudo subdirectories are marked read only regardless of the user s ownership or access rights or the permissions set on the original files Server for NFS periodically polls the system f...

Page 86: ...em will be listed in the backup application as a complete file system snapshot If the built in backup application NTbackup is used the backup software forces a snapshot and then uses the snapshot as t...

Page 87: ...ustered deployment Folder management Volumes and folders on any system are used to organize data Regardless of system size systematic structuring and naming conventions of volumes and folders eases th...

Page 88: ...up and then click Remove The center section of theSecurity tab lists permission levels When new users or groups are added to the permissions list select the appropriate boxes to configure the common f...

Page 89: ...ects with entries shown here that apply to child objects This allows all child folders and files to inherit the current folder permissions by default Modify specific permissions assigned to a particul...

Page 90: ...ed Security Settings is the Auditing tab Auditing allows you to set rules for the auditing of access or attempted access to files or folders Users or groups can be added deleted viewed or modified thr...

Page 91: ...Figure 25 Advanced Security Settings screen Auditing tab Click Add to display the Auditing Entry screen File server management 91...

Page 92: ...to display the Select User or Group screen Figure 27 Select User or Group screen NOTE Click Advanced to search for users or groups Select the user or group Click OK Select the desired Successful and...

Page 93: ...priate user or group in the Change owner to list If it is also necessary to take ownership of subfolders and files enable the Replace owner on subcontainers and objects box Click OK Share management T...

Page 94: ...or domain environment In a multidomain environment user and group permissions from several domains can apply to files stored on the same device Users and groups local to the HPE StoreVirtual 3000 File...

Page 95: ...trators to understand control and manage the quantity and type of data stored on their HPE StoreVirtual 3000 File Controller Some of the tasks you can perform are Quota management File screening manag...

Page 96: ...an organization Create file screening exceptions that extend the flexibility of the file screening rules Storage reports On the Storage Reports node of the File Server Resource Manager snap in you can...

Page 97: ...cannot cancel the installation after the installation starts 6 Click Open Log to view the log files that the system generates during the update installation NOTE For a cluster system you must select i...

Page 98: ...ct access to in depth subsystem information by accessing data reported through the Management Agents For additional information refer to the Management CD in the HPE ProLiant Essentials Foundation Pac...

Page 99: ...ster Utilizing a private network allows communication amongst themselves in order to track the state of each cluster node Each node sends out periodic messages to the other nodes these messages are ca...

Page 100: ...e contained Virtual servers A virtual server is a cluster group that consists of a static IP Address resource and a Network Name resource Several virtual servers can be created By assigning ownership...

Page 101: ...tegrity by Storing the most current version of the cluster database Guaranteeing that only one set of active communicating nodes is allowed to operate as a cluster Cluster concepts Microsoft Failover...

Page 102: ...virtual server names have IP addresses residing on these subnets NOTE If the share is to remain available during a failover each cluster node must be connected to the same network subnet It is impossi...

Page 103: ...tware is required in configurations where multipathing to the storage is desired or required Multipathing software allows for data path failure to occur without forcing a node failover Checklists for...

Page 104: ...s are not presented Power on all nodes Setting up shared disks including the Qurom disk On Off Presented Shut down all nodes Present the shared storage then power on the first node Verifying disk conf...

Page 105: ...s machine name instead of its IP address Verifying domain membership All nodes in the cluster must be members of the same domain and able to access a domain controller and a DNS Server Setting up a cl...

Page 106: ...are not supported in a cluster configuration Dynamic Disks are not supported in a cluster configuration Errors appear on a network adapter that is not configured or does not have an active link If the...

Page 107: ...place each physical disk resource This configuration provides a very coarse level of granularity All resources within a group must remain on the same node Only two IP addresses and network names are r...

Page 108: ...gement tool versus the individual shares on the file system themselves via Windows Explorer Administering them through the Failover Cluster Management tool allows the permissions to migrate from one n...

Page 109: ...ture to a downed server should the resource it is based on fails over to the opposing node Adding new storage to a cluster Present the new storage to one node in the cluster This can be accomplished t...

Page 110: ...System NFS online help provides server cluster information for the following topics Configuring shared folders on a server cluster Configuring an NFS share as a cluster resource Modifying an NFS share...

Page 111: ...quired 5 Create a Print Spool resource 6 To add a printer to the virtual server a Double click the printers and faxes icon b Right click the new screen and then click add printer A wizard starts c Cli...

Page 112: ...g a cluster node causes all cluster resources served by that node to fail over to the other nodes in the cluster based on the failover policy in place Until the failover process completes any currentl...

Page 113: ...des should be powered up separately allowing one node to form the cluster prior to powering up the additional node s To power up the cluster nodes Procedure 1 After the storage subsystem is confirmed...

Page 114: ...rage device to the server for the first time Generic Windows event based troubleshooting Event Viewer can be used for event analysis When Event Viewer is opened the left hand pane displays a folder vi...

Page 115: ...er platform to find specific updates HPE recommends updating the operating system software firmware and NIC drivers simultaneously in the same update window to ensure proper operation of HPE StoreVirt...

Page 116: ...same username and password you use to log in to the server Users who have administrative privileges on the server have the same privileges in the SMH application To view the SMH of one server from an...

Page 117: ...e 30 System Management Homepage main page The page provides system subsystem and status views of the server and displays groupings of systems and their status Troubleshooting servicing and maintenance...

Page 118: ...about the enclosure cooling IDs power Unit Identification LED PCIe devices and I O modules NOTE A large number of disk errors may indicate that an I O module has failed Inspect the I O module LEDs on...

Page 119: ...al number Physical Drives This section provides an overview of all disk drives attached to the controller Drives are identified and grouped as assigned unassigned and spare drives Each physical drive...

Page 120: ...section provides information about system firmware and software Known issues Known issues identifies known issues with HPE StoreVirtual 3000 File Controller when the HPE StoreVirtual 3000 File Control...

Page 121: ...ery These data volumes are not damaged or destroyed but they are not visible after a system recovery operation To restore the mount points to their original locations you must record them prior to run...

Page 122: ...rver has been added to the domain and a cluster has been created Local administrators cannot view this information Once a server is added to a domain and a cluster is created you must log in to Server...

Page 123: ...not be authenticated This may be cause by having multiple interfaces on the same network subnet as that used by the network interface names Cluster Internal By default the Cluster Internal network use...

Page 124: ...xisting between the array and node To register SMI S provider ensure that the array is reachable from the node Perform the following steps on all nodes 1 Open an elevated PowerShell command prompt 2 E...

Page 125: ...For HPE StoreVirtual 3000 File Controller manuals go to www hpe com support Manuals For software related components and issues online help or user guide documentation may offer troubleshooting assista...

Page 126: ...is being renamed If you run the incorrect Smart Component the product name will be set incorrectly but it will not affect your system in any other way Surface Scan Analysis Hewlett Packard Enterprise...

Page 127: ...ess F9 Select System Configuration BIOS Platform Configuration RBSU PCI Device Enable Disable Select Slot 2 HP Store Fabric 8Gb Dual Port PCI e FC HBA FC and disable Figure 33 System Settings Press F1...

Page 128: ...in the correct slot Figure 34 QR error Not a valid configuration pop up appears in System Installation and Recovery window during the QR process Perform the following steps to avoid this erorr Reset t...

Page 129: ...the node is no more part of the cluster In this case rejoin the node to the cluster using Connect to Cluster from the Failover Cluster Manager Could not start the Cluster Service on Local Computer Fi...

Page 130: ...disconnected from the previous cluster Run powershell Run powershell Run as Administrator Remove ClusterNode command to remove the node from a failover cluster and try adding the node to the cluster...

Page 131: ...ClusterNode or Evict node from the Failover Cluster Manager Address the hardware failure with the computer offline bring the machine back up and add the repaired node back to the existing cluster In...

Page 132: ...tem if all other means to boot the server fail While the recovery process makes every attempt to preserve the existing data volumes you must have a backup of your data before recovering the system IMP...

Page 133: ...em that has existing data volumes non operating system volumes is restored using the System Recovery DVD the data volumes will not have drive letters assigned to them This is by design The volume labe...

Page 134: ...ype list disk to determine the USB flash drive number or drive letter and press Enter 4 Note the drive number or drive letter of the USB flash drive 5 Type select disk x where x is the drive number or...

Page 135: ...settings to ensure proper boot sequence 4 Click the option for the StoreEasy System Recovery 5 The recovery process completes with minimal user intervention required The server automatically reboots m...

Page 136: ...However you will not be using the ICT to configure the node 5 Check the Do not show this window at next logon box in the lower left corner of the window and close the ICT window There will be message...

Page 137: ...at the following website to add the recovered server to the cluster 14 http technet microsoft com en us library cc730998 aspx Backing up and restoring HPE StoreVirtual 3000 File Controller with Windo...

Page 138: ...Boot Manager select Windows Recovery Environment The recovery environment is loaded and the System Recovery Options wizard opens Select the keyboard layout Select Troubleshoot to access the repair to...

Page 139: ...restore Verify the system image details and click Finish to start the recovery process Click Yes on the confirmation message to proceed with Windows recovery IMPORTANT Do not interrupt the recovery pr...

Page 140: ...ct improvement or feedback on HPE StoreVirtual 3000 File Controller to storeeasyproductfeedback hpe com You can access the Product Feedback dialog box using the following methods Double click the Prod...

Page 141: ...StoreVirtual with iTernity Compliant Archive Solution iCAS Now validated to meet SEC 17a 4 f requirements A shortcut to iCAS is provided on the desktop and Start screen See the Iternity website for m...

Page 142: ...sm for accessing software updates through the product interface Review your product documentation to identify the recommended software update method To download product updates go to either of the fol...

Page 143: ...veling jacks Install stabilizing feet on the rack In multiple rack installations fasten racks together securely Extend only one rack component at a time Racks can become unstable if more than one comp...

Page 144: ...erprise is committed to providing documentation that meets your needs To help us improve the documentation send any errors suggestions or comments to Documentation Feedback docsfeedback hpe com When s...

Page 145: ...configure the HPE StoreVirtual 3000 File Controller using the factory default settings listed in HPE StoreVirtual 3000 File Controller system RAID configurations HPE StoreVirtual 3000 File Controller...

Page 146: ...get Service TCP 135 135 Any Yes Microsoft iSCSI Software Target Service TCP 3260 3260 Any Yes OEM OOBE Discovery Service WSD IN 3702 Any Yes OEM OOBE Discovery Service WSD OUT Any 3702 Yes LPD Service...

Page 147: ...Traffic In 443 Any Yes World Wide Web Services HTTP Traffic In 80 Any Yes Messaging System HTTP 3202 3202 Any Yes Messaging System HTTP 3201 3201 Any Yes Remote Desktop User Mode TCP In 3389 Any Yes...

Page 148: ...Remote Management HTTP In 5985 Any Yes File and Printer Sharing NB Session In 139 Any Yes File and Printer Sharing NB Session Out Any 139 Yes File and Printer Sharing SMB In 445 Any Yes File and Prin...

Page 149: ...support ProLiantServers Warranties HPE Enterprise Servers www hpe com support EnterpriseServers Warranties HPE Storage Products www hpe com support Storage Warranties HPE Networking Products www hpe...

Page 150: ...000 as the starting point for example 238 2 for 2002 and 38 for the week of September 9 In addition 2010 is indicated by 0 2011 by 1 2012 by 2 2013 by 3 and so forth YYWW where YY indicates the year u...

Reviews: