Procedure
1.
Observe the following alerts.
CAUTION:
When handling the heatsink, always hold it along the top and bottom of the fins. Holding it from the
sides can damage the fins.
CAUTION:
To avoid damage to the processor or system board, only authorized personnel should attempt to
replace or install the processor in this server.
CAUTION:
To prevent possible server malfunction and damage to the equipment, multiprocessor configurations
must contain processors with the same part number.
CAUTION:
If installing a processor with a faster speed, update the system ROM before installing the processor.
To download firmware and view installation instructions, see the
CAUTION:
THE CONTACTS ARE VERY FRAGILE AND EASILY DAMAGED.
To avoid damage to the socket
or processor, do not touch the contacts.
.
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
•
Extend the server from the rack
.
•
Remove the server from the rack
6.
Do one of the following:
•
•
If installed, remove the 4LFF midplane drive cage
.
7.
Install the processor heatsink assembly:
a.
Remove the dust cover.
b.
Locate the Pin 1 indicator on the processor frame and the socket.
c.
Align the processor heatsink assembly with the alignment posts and gently lower it down until it sits
evenly on the socket.