Description
Chassis
Fan configuration
Number of drives
supported by the
server
Maximum inlet
ambient temperature
Apollo DX2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
30°C (86°F)
Apollo DX2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 4 drives
30°C (86°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
If the component is installed in server 1 or server 2, and the server is installed in the Apollo DX2200 Gen10 Chassis,
drive blanks must be installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3 or server 4,
and the server is installed in the Apollo DX2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and
4-2.
Fibre Channel and Converged Network adapters
Description
Chassis
Fan configuration
Number of drives
supported by the
server
Maximum inlet
ambient temperature
FC HBA
Apollo
DX2200
Gen10
Chassis
(12 LFF
backplane)
Redundant and
nonredundant
Not supported
Not supported
22°C (71°F)
Apollo
DX2600
Gen10
Chassis
(24 SFF or 16
SFF + 8
NVMe
backplane)
Redundant and
nonredundant
0 to 6 drives
Not supported
Apollo
DX2800
Gen10
Chassis
(24 SFF
backplane
with SAS
expander)
Redundant and
nonredundant
0 to 24 drives
Not supported
Table Continued
110
Specifications