Specification
Value
BTUs per hour
2,964 at 200 VAC
2,951 at 230 VAC
2,936 at 277 VAC
Power supply output
Rated steady-state power
800 W at 200 VAC to 277 VAC input
Maximum peak power
800 W at 200 VAC to 277 VAC input
HPE 800W Flex Slot -48VDC Hot Plug Low Halogen Power Supply
Specification
Value
Input requirements
Rated input voltage
-40 VDC to -72 VDC
-48 VDC nominal input
Rated input current
24 A at -40 VDC input
19 A at -48 VDC input, nominal input
12.4 A at -72 VDC input
Rated input power (W)
874 W at -40 VDC input
865 W at -48 VDC input, nominal input
854 W at -72 VDC input
Rated input power (BTUs per hour)
2,983 at -40 VDC input
2,951 at -48 VDC input, nominal input
2,912 at -72 VDC input
Power supply output
Rated steady-state power (W)
800 W at -40 VDC to -72 VDC
Maximum peak power (W)
800 W at -40 VDC to -72 VDC
Maximum peak power
800 W at 200 VAC to 277 VAC input
800 W at 380 VDC input
WARNING:
To reduce the risk of electric shock or energy hazards:
• This equipment must be installed by trained service personnel.
• Connect the equipment to a reliably grounded secondary circuit source. A secondary circuit has no
direct connection to a primary circuit and derives its power from a transformer, converter, or
equivalent isolation device.
• The branch circuit overcurrent protection must be rated 27 A.
Specifications
161
Summary of Contents for ProLiant DL388 Gen10
Page 37: ...Customer self repair 37...
Page 38: ...38 Customer self repair...
Page 39: ...Customer self repair 39...
Page 147: ...Option 1 System board Option 2 Controller Option 3 not shown SAS Expander Cabling 147...
Page 149: ...Box 1 to SAS Expander Box 2 to SAS Expander Cabling 149...
Page 151: ...Cable routing Front 8SFF NVMe drive options Box 1 Box 2 Cabling 151...
Page 152: ...Box 3 Cable routing Front 2SFF NVMe drive option for SFF 152 Cabling...