Drive LEDs and buttons
Low profile LFF drive LED definitions
Item
LED
Status
Definition
1
Fault
\Locate
Solid amber
The drive has failed.
Solid blue
The drive is operating normally and being identified by a
management application.
Flashing amber/blue
(1 flash per second)
The drive has failed, or a predictive failure alert has been
received for this drive; it also has been identified by a
management application.
Flashing amber
(1 flash per second)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
2
Online
\Activity
Solid green
The drive is online and has no activity.
Flashing green
(4 flashes per second)
The drive is operating normally and has activity.
Flashing green
(1 flash per second)
The drive is doing one of the following:
• Rebuilding
• Performing a RAID migration
• Performing a strip size migration
• Performing a capacity expansion
• Performing a logical drive extension
• Erasing
• Spare part activation
Off
The drive is not configured by a RAID controller or a spare
drive.
108