14. Connect all necessary external cabling to the expansion board.
For more information on these cabling requirements, see the documentation that ships with the option.
15. Connect all peripheral cables to the server.
16. Connect each power cord to the server.
17. Connect each power cord to the power source.
19. If removed, install the bezel.
The installation is complete.
Installing the HPE 12GB SAS expander card
NOTE: The SAS expander card can be installed only in slot 1 of the primary riser.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
• SAS expander option
• Internal and external cabling required by the SAS expander
•
Smart Array type-a modular controller installed
• T-15 Torx screwdriver
Procedure
1.
If installed,
2.
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Disconnect all peripheral cables from the server.
5.
Remove the server from the rack.
6.
7.
Remove the primary riser cage.
8.
Remove the primary riser blank from slot 1 of the riser cage.
9.
Connect all cables to the SAS expander card.
10. Install the SAS expander card in slot 1 of the primary riser.
90
Hardware options installation
Summary of Contents for ProLiant DL325 Gen10 Plus
Page 36: ...10 Remove the inner drive cage blank 11 Remove the fan wall covers 36 Operations...
Page 37: ...12 For SFF drive cage remove the cable covers 13 Remove the drive cage latches Operations 37...
Page 38: ...14 Remove the outer drive cage LFF SFF 38 Operations...
Page 52: ...52 Operations...
Page 67: ...3 Remove the drive blank LFF SFF 4 Prepare the drive LFF Hardware options installation 67...
Page 119: ...SFF Cable routing Front I O LFF Cabling 119...
Page 120: ...SFF Cable routing Serial port 120 Cabling...