Extending the server from the rack
About this task
CAUTION:
To reduce the risk of personal injury or equipment damage, be sure that the rack is adequately stabilized
before extending a component from the rack.
Procedure
1.
2.
Disconnect all peripheral cables from the server.
3.
Disconnect each power cord from the server.
4.
In a server that uses thumbscrew rack ears, loosen the captive thumbscrews that secure the server
faceplate to the front of the rack, then slide the server out of the rack.
5.
In a server that uses quick-release latch rack ears:
a.
Open the latches on both sides of the server.
b.
If necessary, use a T-25 Torx screwdriver to loosen the shipping screws.
c.
Slide the server out of the rack.
Extending the server from the rack
27