Installing the two-bay SFF drive cage option
Installing the two-bay SFF drive cage option
For additional storage capacity, install the 2 SFF hot-plug drive cage option in the media bay of the SFF chassis. This drive cage option
supports SAS, SATA, or U.3 NVMe drives.
CAUTION:
CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
Prerequisites
Prerequisites
A Flexible Slot power supply is required in 4 + 2 SFF hot-plug drive configurations .
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
Procedure
1. If installed, remove the front bezel .
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
8. Remove the media bay blank:
a. Remove the media bay blank screws (callout 1).
Retain all screws for future use.
b. Disengage the media bay blank (callout 2).
c. Remove the media bay blank (callout 3).
Retain the blank for future use.
9. Install the 2 SFF hot-plug drive cage:
Installing the two-bay SFF drive cage option
95
Summary of Contents for ProLiant DL20 Gen10 Plus
Page 20: ...DIMM slot location The arrow points to the front of the server DIMM slot location 20 ...
Page 30: ...Fan numbering Fan numbering 30 ...
Page 100: ...Installing an optical drive in the LFF drive chassis 100 ...
Page 169: ...Energy pack cabling Energy pack cabling 169 ...
Page 174: ...M 2 SATA SSD add in card cabling 174 ...
Page 177: ...Chassis intrusion detection switch cabling Chassis intrusion detection switch cabling 177 ...
Page 178: ...Serial port cabling Serial port cabling 178 ...
Page 180: ...Power supply cabling 180 ...
Page 185: ...Troubleshooting NMI functionality Troubleshooting resources Troubleshooting 185 ...
Page 196: ...Ukraine RoHS material content declaration Ukraine RoHS material content declaration 196 ...